CoChat

Where Did the Linker-Payload Go? A Quantitative Investigation on the Destination of the Released Linker-Payload from an Antibody-Drug Conjugate with a Maleimide Linker in Plasma

Wei, Cong, Zhang, Guodong, Clark, Tracey, Barletta, Frank, Tumey, L. Nathan, Rago, Brian, Hansel, Steven, Han, Xiaogang · 2016 · Analytical Chemistry
Cited by 105

The DOI matches its Crossref record.

Abstract

The reactive thiol of cysteine is often used for coupling maleimide-containing linker-payloads to antibodies resulting in the generation of antibody drug conjugates (ADCs). Currently, a numbers of ADCs in drug development are made by coupling a linker-payload to native or engineered cysteine residues on the antibody. An ADC conjugated via hinge-cysteines to an auristatin payload was used as a model in this study to understand the impact of the maleimide linkers on ADC stability. The payload was conjugated to trastuzumab by a protease-cleavable linker, maleimido-caproyl-valine-citruline-p-amino-benzyloxy carbonyl (mcVC-PABC). In plasma stability assays, when the ADC (Trastuzumab-mcVC-PABC-Auristatin-0101) was incubated with plasma over a 144-h time-course, a discrepancy was observed between the measured released free payload concentration and the measured loss of drug-to-antibody ratio (DAR), as measured by liquid chromatography-mass spectrometry (LC-MS). We found that an enzymatic release of payload from ADC-depleted human plasma at 144 h was able to account for almost 100% of the DAR loss. Intact protein mass analysis showed that at the 144 h time point, the mass of the major protein in ADC-depleted human plasma had an additional 1347 Da over the native albumin extracted from human plasma, exactly matching the mass of the linker-payload. In addition, protein gel electrophoresis showed that there was only one enriched protein in the 144 h ADC-depleted and antipayload immunoprecipitated plasma sample, as compared to the 0 h plasma immunoprecipitated sample, and the mass of this enriched protein was slightly heavier than the mass of serum albumin. Furthermore, the albumin adduct was also identified in 96 h and 168 h postdose in vivo cynomolgus monkey plasma. These results strongly suggest that the majority of the deconjugated mc-VC-PABC-auristatin ultimately is transferred to serum albumin, forming a long-lived albumin-linker-payload adduct. To our knowledge, this is the first report quantitatively characterizing the extent of linker-payload transfer to serum albumin and the first clear example of in vivo formation of an albumin-linker-payload adduct.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.6b00976

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wei, C., Zhang, G., Clark, T., Barletta, F., Tumey, L. N., Rago, B., Hansel, S., & Han, X.
Venue
Analytical Chemistry
Published
2016-04-21
Volume
88
Issue
9
Pages
4979-4986
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2337369926
Cited by
105
References
0
FWCI
7.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.