The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
One-Pot Synthesis of Fluorescent Silicon Nanoparticles for Sensitive and Selective Determination of 2,4,6-Trinitrophenol in Aqueous Solution
Abstract
Because 2,4,6-trinitrophenol (TNP) and its analogues such as 2,4,6-trinitrotoluene (TNT) possess similar chemical structures and properties, the reliable and accurate detection of TNP from its analogues still remains a challenging task. In the present work, a selective and sensitive method based on the water-soluble silicon nanoparticles (SiNPs) for the determination of TNP was established. The SiNPs with good thermostability and excellent antiphotobleaching capability were prepared via a simple one-pot method. Compared with the synthesized time of other nanomaterials with respect to the detection of TNP, this method avoided a multistep and time-consuming synthesis procedure. Significantly, the fluorescence of the SiNPs could be remarkably quenched by TNP via an inner filter effect. A wide linear range was obtained from 0.02 to 120 μg/mL with a limit of detection of 6.7 ng/mL. The method displayed excellent selectivity toward TNP over other nitroaromatic explosives. The proposed fluorescent method was successfully applied to the analysis of TNP. Moreover, a straightforward and convenient fluorescent filter paper sensor was developed for the detection of TNP, providing a valuable platform for TNP sensing in public safety and security.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luminescent metal–organic frameworks for chemical sensing and explosive detection
Hu, Z., Deibert, B. J., & Li, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00010b · Cited by 4,169
Dong, Y., Pang, H., Yang, H. B., Guo, C., Shao, J., Chi, Y., Li, C. M., & Yu, T. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201301114 · Cited by 2,267
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Instrumentation for trace detection of high explosives
Moore, D. S. (2004) · Review of Scientific Instruments · doi:10.1063/1.1771493 · Cited by 812
Gauthier, T. D., Shane, E. C., Guerin, W. F., Seitz, W. R., & Grant, C. L. (1986) · Environmental Science & Technology · doi:10.1021/es00153a012 · Cited by 598
Zhang, K., Zhou, H., Mei, Q., Wang, S., Guan, G., Liu, R., Zhang, J., & Zhang, Z. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2015873 · Cited by 547
Zhong, Y., Peng, F., Bao, F., Wang, S., Ji, X., Yang, L., Su, Y., Lee, S.-T., & He, Y. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4026227 · Cited by 430
Erogbogbo, F., Yong, K.-T., Roy, I., Hu, R., Law, W.-C., Zhao, W., Ding, H., Wu, F., Kumar, R., Swihart, M. T., et al. (2011) · ACS Nano · doi:10.1021/nn1018945 · Cited by 418
Lin, L., Rong, M., Lu, S., Song, X., Zhong, Y., Yan, J., Wang, Y., & Chen, X. (2015) · Nanoscale · doi:10.1039/c4nr06365a · Cited by 403
Self-citationZhai, W., Wang, C., Yu, P., Wang, Y., & Mao, L. (2014) · Analytical Chemistry · doi:10.1021/ac503215z · Cited by 368
Metadata
- Authors
- Han, Y., Chen, Y., Feng, J., Liu, J., Ma, S., & Chen, X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-02-21
- Volume
- 89
- Issue
- 5
- Pages
- 3001-3008
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2587538963
- Cited by
- 295
- References
- 26
- FWCI
- 14.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One-Pot Synthesis of Fluorescent Silicon Nanoparticles for Sensitive and Selective Determination of 2,4,6-Trinitrophenol in Aqueous Solution. https://app.cochat.ai/papers/10.1021/acs.analchem.6b04509
- The paper
- Han, Y., Chen, Y., Feng, J., Liu, J., Ma, S., & Chen, X. (2017). One-Pot Synthesis of Fluorescent Silicon Nanoparticles for Sensitive and Selective Determination of 2,4,6-Trinitrophenol in Aqueous Solution. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6b04509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.