Gas Cluster Ion Beam Time-of-Flight Secondary Ion Mass Spectrometry High-Resolution Imaging of Cardiolipin Speciation in the Brain: Identification of Molecular Losses after Traumatic Injury
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Gas cluster ion beam-secondary ion mass spectrometry (GCIB-SIMS) has shown the full potential of mapping intact lipids in biological systems with better than 10 μm lateral resolution. This study investigated further the capability of GCIB-SIMS in imaging high-mass signals from intact cardiolipin (CL) and gangliosides in normal brain and the effect of a controlled cortical impact model (CCI) of traumatic brain injury (TBI) on their distribution. A combination of enzymatic and chemical treatments was employed to suppress the signals from the most abundant phospholipids (phosphatidylcholine (PC) and phosphatidylethanolamine (PE)) and enhance the signals from the low-abundance CLs and gangliosides to allow their GCIB-SIMS detection at 8 and 16 μm spatial resolution. Brain CLs have not been observed previously using other contemporary imaging mass spectrometry techniques at better than 50 μm spatial resolution. High-resolution images of naive and injured brain tissue facilitated the comparison of CL species across three multicell layers in the CA1, CA3, and DG regions of the hippocampus. GCIB-SIMS also reliably mapped losses of oxidizable polyunsaturated CL species (but not the oxidation-resistant saturated and monounsaturated gangliosides) to regions including the CA1 and CA3 of the hippocampus after CCI. This work extends the detection range for SIMS measurements of intact lipids to above m/z 2000, bridging the mass range gap compared with MALDI. Further advances in high-resolution SIMS of CLs, with the potential for single cell or supra-cellular imaging, will be essential for the understanding of CL's functional and structural organization in normal and injured brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schlame, M. (2008) · Journal of Lipid Research · doi:10.1194/jlr.r700018-jlr200 · Cited by 388
The complexity of cardiolipin in health and disease
Claypool, S. M., & Koehler, C. M. (2012) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2011.09.003 · Cited by 345
Cited by
Mass Spectrometry Imaging: A Review of Emerging Advancements and Future Insights
Buchberger, A. R., DeLaney, K., Johnson, J., & Li, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04733 · Cited by 1,029
Metabolomics and mass spectrometry imaging reveal channeled de novo purine synthesis in cells
Pareek, V., Tian, H., Winograd, N., & Benkovic, S. J. (2020) · Science · doi:10.1126/science.aaz6465 · Cited by 307
Self-citationYin, R., Burnum-Johnson, K. E., Sun, X., Dey, S. K., & Laskin, J. (2019) · Nature Protocols · doi:10.1038/s41596-019-0237-4 · Cited by 220
Porta Siegel, T., Hamm, G., Bunch, J., Cappell, J., Fletcher, J. S., & Schwamborn, K. (2018) · Molecular Imaging and Biology · doi:10.1007/s11307-018-1267-y · Cited by 187
“While treatment of the sample with exogenous compounds is not required, there can be benefits of preparation with reactive vapour [44, 46], the addition of a MALDI-type matrix [47, 48] or biochemical reactions on the surface of the sample [49].”
BackgroundApplications of Mass Spectrometry for Clinical Diagnostics: The Influence of Turnaround Time
Swiner, D. J., Jackson, S., Burris, B. J., & Badu-Tawiah, A. K. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04901 · Cited by 73
Metadata
- Authors
- Tian, H., Sparvero, L. J., Amoscato, A. A., Bloom, A., Bayır, H., Kagan, V. E., & Winograd, N.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-03-29
- Volume
- 89
- Issue
- 8
- Pages
- 4611-4619
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2597101834
- Cited by
- 82
- References
- 2
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.