The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Detailed Investigation and Comparison of the XCMS and MZmine 2 Chromatogram Construction and Chromatographic Peak Detection Methods for Preprocessing Mass Spectrometry Metabolomics Data
Abstract
XCMS and MZmine 2 are two widely used software packages for preprocessing untargeted LC/MS metabolomics data. Both construct extracted ion chromatograms (EICs) and detect peaks from the EICs, the first two steps in the data preprocessing workflow. While both packages have performed admirably in peak picking, they also detect a problematic number of false positive EIC peaks and can also fail to detect real EIC peaks. The former and latter translate downstream into spurious and missing compounds and present significant limitations with most existing software packages that preprocess untargeted mass spectrometry metabolomics data. We seek to understand the specific reasons why XCMS and MZmine 2 find the false positive EIC peaks that they do and in what ways they fail to detect real compounds. We investigate differences of EIC construction methods in XCMS and MZmine 2 and find several problems in the XCMS centWave peak detection algorithm which we show are partly responsible for the false positive and false negative compound identifications. In addition, we find a problem with MZmine 2's use of centWave. We hope that a detailed understanding of the XCMS and MZmine 2 algorithms will allow users to work with them more effectively and will also help with future algorithmic development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Human Serum Metabolome (HUSERMET) Consortium, Dunn, W. B., Broadhurst, D., Begley, P., Zelena, E., Francis-McIntyre, S., Anderson, N., Brown, M., Knowles, J. D., Halsall, A., et al. (2011) · Nature Protocols · doi:10.1038/nprot.2011.335 · Cited by 3,294
Metabolomics by Gas Chromatography–Mass Spectrometry: Combined Targeted and Untargeted Profiling
Fiehn, O. (2016) · Current Protocols in Molecular Biology · doi:10.1002/0471142727.mb3004s114 · Cited by 917
Scalbert, A., Brennan, L., Fiehn, O., Hankemeier, T., Kristal, B. S., van Ommen, B., Pujos-Guillot, E., Verheij, E., Wishart, D., & Wopereis, S. (2009) · Metabolomics · doi:10.1007/s11306-009-0168-0 · Cited by 565
Confidence Intervals for Proportions and Related Measures of Effect Size
Newcombe, R. G. (2012) · doi:10.1201/b12670 · Cited by 135
Cited by
Pang, Z., Lu, Y., Zhou, G., Hui, F., Xu, L., Viau, C., Spigelman, A. F., MacDonald, P. E., Wishart, D. S., Li, S., et al. (2024) · Nucleic Acids Research · doi:10.1093/nar/gkae253 · Cited by 2,291
Self-citationGuo, J., & Huan, T. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05135 · Cited by 312
Wu, E., Wang, K., Liu, Z., Wang, J., Yan, H., Zhu, X., Zhu, X., & Chen, B. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c07020 · Cited by 88
Metadata
- Authors
- Myers, O. D., Sumner, S. J., Li, S., Barnes, S., & Du, X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-17
- Volume
- 89
- Issue
- 17
- Pages
- 8689-8695
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2740838806
- Cited by
- 197
- References
- 4
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.