Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Dual-Signal Readout Nanospheres for Rapid Point-of-Care Detection of Ebola Virus Glycoprotein

Hu, Jiao, Jiang, Yong-Zhong, Wu, Ling-Ling, Wu, Zhen, Bi, Yuhai, Wong, Gary, Qiu, Xiangguo, Chen, Jianjun, Pang, Dai-Wen, Zhang, Zhi-Ling·2017·Analytical Chemistry

Abstract

Rapid detection of highly contagious pathogens is the key to increasing the probability of survival and reducing infection rates. We developed a sensitive and quantitative lateral flow assay for detection of Ebola virus (EBOV) glycoprotein with a novel multifunctional nanosphere (RNs@Au) as a reporter. Each RNs@Au contains hundreds of quantum dots and dozens of Au nanoparticles and can achieve enhanced dual-signal readout (fluorescence signal for quantitative detection and colorimetric signal for visual detection). Antibody (Ab) and streptavidin (SA) were simultaneously modified onto the RNs@Au to label the target and act as signal enhancer. After the target was labeled by the Ab-RNs@Au-SA and captured on the test line, biotin-modified RNs@Au was used to amplify the dual signal by the reaction of SA with biotin. The assay enables naked-eye detection of 2 ng/mL glycoprotein within 20 min, and the quantitative detection limit is 0.18 ng/mL. Additionally, the assay has been successfully tested in field work for detecting EBOV in spiked urine, plasma, and tap water samples and is thus a promising candidate for early diagnosis of suspect infections in EBOV-stricken areas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b02222

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Hu, J., Jiang, Y.-Z., Wu, L.-L., Wu, Z., Bi, Y., Wong, G., Qiu, X., Chen, J., Pang, D.-W., & Zhang, Z.-L.
Venue
Analytical Chemistry
Published
2017-12-01
Volume
89
Issue
24
Pages
13105-13111
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2769209484
Cited by
159
References
1
FWCI
5.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual-Signal Readout Nanospheres for Rapid Point-of-Care Detection of Ebola Virus Glycoprotein. https://app.cochat.ai/papers/10.1021/acs.analchem.7b02222
The paper
Hu, J., Jiang, Y.-Z., Wu, L.-L., Wu, Z., Bi, Y., Wong, G., Qiu, X., Chen, J., Pang, D.-W., & Zhang, Z.-L. (2017). Dual-Signal Readout Nanospheres for Rapid Point-of-Care Detection of Ebola Virus Glycoprotein. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b02222

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.