The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Paper–Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine
Abstract
In this work, a disposable paper-plastic hybrid microfluidic lab-on-a-chip (LOC) has been developed and successfully applied for the colorimetric measurement of urine by the smartphone-based optical platform using a "UrineAnalysis" Android app. The developed device was cost-effectively implemented as a stand-alone hybrid LOC by incorporating the paper-based conventional reagent test strip inside the plastic-based LOC microchannel. The LOC device quantitatively investigated the small volume (40 μL) of urine analytes for the colorimetric reaction of glucose, protein, pH, and red blood cell (RBC) in integration with the finger-actuating micropump. On the basis of our experiments, the conventional urine strip showed large deviation as the reaction time goes by, because dipping the strip sensor in a bottle of urine could not control the reaction volume. By integrating the strip sensor in the LOC device for urine analysis, our device significantly improves the time-dependent inconstancy of the conventional dipstick-based urine strip, and the smartphone app used for image analysis enhances the visual assessment of the test strip, which is a major user concern for the colorimetric analysis in point-of-care (POC) applications. As a result, the user-friendly LOC, which is successfully implemented in a disposable format with the smartphone-based optical platform, may be applicable as an effective tool for rapid and qualitative POC urinalysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy
Devillé, W. L., Yzermans, J. C., van Duijn, N. P., Bezemer, P. D., van der Windt, D. A., & Bouter, L. M. (2004) · BMC Urology · doi:10.1186/1471-2490-4-4 · Cited by 519
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285
Cited by
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Yang, S.-M., Lv, S., Zhang, W., & Cui, Y. (2022) · Sensors · doi:10.3390/s22041620 · Cited by 299
Applications, challenges, and needs for employing synthetic biology beyond the lab
Brooks, S. M., & Alper, H. S. (2021) · Nature Communications · doi:10.1038/s41467-021-21740-0 · Cited by 286
Recent patient health monitoring platforms incorporating internet of things-enabled smart devices
Kang, M., Park, E., Cho, B. H., & Lee, K.-S. (2018) · International Neurourology Journal · doi:10.5213/inj.1836144.072 · Cited by 143
Metadata
- Authors
- Jalal, U. M., Jin, G. J., & Shim, J. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-28
- Volume
- 89
- Issue
- 24
- Pages
- 13160-13166
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2768172189
- Cited by
- 159
- References
- 3
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Paper–Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine. https://app.cochat.ai/papers/10.1021/acs.analchem.7b02612
- The paper
- Jalal, U. M., Jin, G. J., & Shim, J. S. (2017). Paper–Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b02612
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.