The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Validating Quantitative Untargeted Lipidomics Across Nine Liquid Chromatography–High-Resolution Mass Spectrometry Platforms
Abstract
Liquid chromatography-mass spectrometry (LC-MS) methods are most often used for untargeted metabolomics and lipidomics. However, methods have not been standardized as accepted "best practice" documents, and reports lack harmonization with respect to quantitative data that enable interstudy comparisons. Researchers use a wide variety of high-resolution mass spectrometers under different operating conditions, and it is unclear if results would yield different biological conclusions depending on the instrument performance. To this end, we used 126 identical human plasma samples and 29 quality control samples from a nutritional intervention study. We investigated lipidomic data acquisitions across nine different MS instruments (1 single TOF, 1 Q/orbital ion trap, and 7 QTOF instruments). Sample preparations, chromatography conditions, and data processing methods were kept identical. Single-point internal standard calibrations were used to estimate absolute concentrations for 307 unique lipids identified by accurate mass, MS/MS spectral match, and retention times. Quantitative results were highly comparable between the LC-MS platforms tested. Using partial least-squares discriminant analysis (PLS-DA) to compare results between platforms, a 92% overlap for the most discriminating lipids based on variable importance in projection (VIP) scores was achieved for all lipids that were detected by at least two instrument platforms. Importantly, even the relative positions of individual samples on the PLS-DA projections were identical. The key for success in harmonizing results was to avoid ion saturation by carefully evaluating linear dynamic ranges using serial dilutions and adjusting the resuspension volume and/or injection volume before running actual study samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lipidomics reveals a remarkable diversity of lipids in human plasma
Quehenberger, O., Armando, A. M., Brown, A. H., Milne, S. B., Myers, D. S., Merrill, A. H., Bandyopadhyay, S., Jones, K. N., Kelly, S., Shaner, R. L., et al. (2010) · Journal of Lipid Research · doi:10.1194/jlr.m009449 · Cited by 1,341
Siskos, A. P., Jain, P., Römisch-Margl, W., Bennett, M., Achaintre, D., Asad, Y., Marney, L., Richardson, L., Koulman, A., Griffin, J. L., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02930 · Cited by 269
Gika, H. G., Theodoridis, G. A., Earll, M., Snyder, R. W., Sumner, S. J., & Wilson, I. D. (2010) · Analytical Chemistry · doi:10.1021/ac1016612 · Cited by 61
Cited by
Proteomics reveals NNMT as a master metabolic regulator of cancer-associated fibroblasts
Eckert, M. A., Coscia, F., Chryplewicz, A., Chang, J. W., Hernandez, K. M., Pan, S., Tienda, S. M., Nahotko, D. A., Li, G., Blaženović, I., et al. (2019) · Nature · doi:10.1038/s41586-019-1173-8 · Cited by 503
Self-citationPhysiological blood–brain transport is impaired with age by a shift in transcytosis
Yang, A. C., Stevens, M. Y., Chen, M. B., Lee, D. P., Stähli, D., Gate, D., Contrepois, K., Chen, W., Iram, T., Zhang, L., et al. (2020) · Nature · doi:10.1038/s41586-020-2453-z · Cited by 477
A metabolomics pipeline for the mechanistic interrogation of the gut microbiome
Han, S., Van Treuren, W., Fischer, C. R., Merrill, B. D., DeFelice, B. C., Sanchez, J. M., Higginbottom, S. K., Guthrie, L., Fall, L. A., Dodd, D., et al. (2021) · Nature · doi:10.1038/s41586-021-03707-9 · Cited by 409
Lipidomics from sample preparation to data analysis: a primer
Züllig, T., Trötzmüller, M., & Köfeler, H. C. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02241-y · Cited by 360
Systematic Error Removal Using Random Forest for Normalizing Large-Scale Untargeted Lipidomics Data
Fan, S., Kind, T., Cajka, T., Hazen, S. L., Tang, W. H. W., Kaddurah-Daouk, R., Irvin, M. R., Arnett, D. K., Barupal, D. K., & Fiehn, O. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05592 · Cited by 336
Self-citation
Metadata
- Authors
- Cajka, T., Smilowitz, J. T., & Fiehn, O.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-07
- Volume
- 89
- Issue
- 22
- Pages
- 12360-12368
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2767195265
- Cited by
- 241
- References
- 3
- FWCI
- 7.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.