The DOI matches its Crossref record.
3D Network and 2D Paper of Reduced Graphene Oxide/Cu2O Composite for Electrochemical Sensing of Hydrogen Peroxide
Open accessAbstract
In this study, two-dimensional (2D) and three-dimensional (3D) freestanding reduced graphene oxide-supported Cu2O composites (Cu2O-rGO) were synthesized via simple and cost-efficient hydrothermal and filtration strategies. The structural characterizations clearly showed that highly porous 3D graphene aerogel-supported Cu2O microcrystals (3D Cu2O-GA) have been successfully synthesized, and the Cu2O microcrystals are uniformly assembled in the 3D GA. Meanwhile, paper-like 2D reduced graphene oxide-supported Cu2O nanocrystals (2D Cu2O-rGO-P) have also been prepared by a filtration process. It was found that the products prepared from different precursors and methods exhibited different sensing performances for H2O2 detection. The electrochemical measurements demonstrated that the 3D Cu2O-GA has high electrocatalytic activity for the H2O2 reduction and excellent sensing performance for the electrochemical detection of H2O2 with a detection limit of 0.37 μM and a linear detection range from 1.0 μM to 1.47 mM. Meanwhile, the 2D Cu2O-rGO-P structure also showed good electrochemical sensing performance toward H2O2 detection with a much wider linear response over the concentration range from 5.0 μM to 10.56 mM. Compared to the previously reported sensing materials, the as-obtained 2D and 3D Cu2O-rGO materials exhibited higher electrochemical sensing properties toward the detection of H2O2 with high sensitivity and selectivity. The 2D and 3D Cu2O-rGO composites also exhibited high sensing performance for the real-time detection of H2O2 in human serum. The present study indicates that 2D and 3D graphene-Cu2O composites have promising applications in the fabrication of nonenzymatic electrochemical sensing devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Carbon Nanomaterials: Synthesis, Functionalization and Sensing Applications
Speranza, G. (2021) · Nanomaterials · doi:10.3390/nano11040967 · Cited by 418
Flexible Electronics Based on Micro/Nanostructured Paper
Zhang, Y., Zhang, L., Cui, K., Ge, S., Cheng, X., Yan, M., Yu, J., & Liu, H. (2018) · Advanced Materials · doi:10.1002/adma.201801588 · Cited by 380
Green Flexible Electronics: Natural Materials, Fabrication, and Applications
Hui, Z., Zhang, L., Ren, G., Sun, G., Yu, H., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202211202 · Cited by 287
Chen, T.-W., Ramachandran, R., Chen, S.-M., Anushya, G., & Ramachandran, K. (2020) · Sensors · doi:10.3390/s20236755 · Cited by 37
Metadata
- Authors
- Cheng, C., Zhang, C., Gao, X., Zhuang, Z., Du, C., & Chen, W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-12-29
- Volume
- 90
- Issue
- 3
- Pages
- 1983-1991
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2779091280
- Cited by
- 180
- References
- 0
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.