Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 216

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Highly Sensitive Detection of Salmonella typhimurium Using a Colorimetric Paper-Based Analytical Device Coupled with Immunomagnetic Separation

Srisa-Art, Monpichar, Boehle, Katherine E., Geiss, Brian J., Henry, Charles S. · 2018 · Analytical Chemistry

Abstract

Salmonella causes over a million foodborne illnesses per year in the United States resulting in more hospitalizations and deaths than any other foodborne bacterial pathogen. To help prevent outbreaks, a rapid, portable, sensitive, and reliable method for onsite detection of bacteria that can be used in different sample matrices would be beneficial. Herein, we present a colorimetric paper-based analytical device (PAD) combined with immunomagnetic separation (IMS) for detecting Salmonella typhimurium . IMS anti- Salmonella coated magnetic beads were applied to capture and separate bacteria from the sample matrix and preconcentrate it into small volumes before testing on paper. To directly detect S. typhimurium after IMS, a sandwich immunoassay was implemented into the procedure with β-galactosidase (β-gal) as the detection enzyme. Using the antibody/enzyme complex, we performed a colorimetric assay with chlorophenol red-β- d -galactopyranoside (CPRG) for bacteria quantification. The method was confirmed to be highly specific to S. typhimurium without interference from other pathogenic bacteria like Escherichia coli . Using this system, the limit of detection of S. typhimurium was found to be 10 2 CFU mL –1 in culturing solution without any pre-enrichment. In addition, distance-based detection where the concentration is read as the length of colored band formed on the reaction was also demonstrated. This assay had a detection limit of 10 2 CFU mL –1 for S. typhimurium, providing an instrument-free quantitative analysis alternative to spot tests, which require image analysis. Finally, the proposed platform was applied for detection of S. typhimurium in inoculated Starling bird fecal samples and whole milk with detection limits of 10 5 CFU g –1 and 10 3 CFU mL –1, respectively, and this is the first published paper-based detection method for S. typhimurium in bird feces and whole milk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b04628

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 216

Metadata

Authors
Srisa-Art, M., Boehle, K. E., Geiss, B. J., & Henry, C. S.
Venue
Analytical Chemistry
Published
2017-12-20
Volume
90
Issue
1
Pages
1035-1043
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2771911495
Cited by
216
References
1
FWCI
8.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.