Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 348

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Double Photosystems-Based ‘Z-Scheme’ Photoelectrochemical Sensing Mode for Ultrasensitive Detection of Disease Biomarker Accompanying Three-Dimensional DNA Walker

Lv, Shuzhen, Zhang, Kangyao, Zeng, Yongyi, Tang, Dianping·2018·Analytical Chemistry

Abstract

A new double photosystems-based ‘Z-scheme’ photoelectrochemical (PEC) sensing platform is designed for ultrasensitive detection of prostate-specific antigen (PSA) by coupling with a three-dimensional (3D) DNA walker. Two photosystems consist of CdS quantum dots (photosystem I; PS I) and BiVO 4 photoactive materials (photosystem II; PS II), whereas gold nanoparticles (AuNPs) photodeposited on high-active {010} facets of BiVO 4 are used as the electron mediators to promote electron transfer from conduction band of PS II to valence band of PS I. 3D DNA walker-based amplification strategy is carried out between hairpin DNA1 conjugated onto the AuNP, hairpin DNA2 labeled with CdS quantum dot (QD-H2), and DNA walker complementary with the PSA aptamer modified to a magnetic bead (Apt-MB). Upon addition of target, DNA walker strand is displaced from DNA walker/Apt-MB to open hairpin DNA1 on AuNP@BiVO 4 . In the presence of QD-H2, DNA walker induces the hybridization of DNA1 with DNA2 on the gold nanoparticles step by step, thereby resulting in the assembly of CdS QDs on the AuNP@BiVO 4 to form Z-scheme double photosystems with strong photocurrent. Under optimum conditions, the Z-scheme PEC sensing system exhibits good photocurrent responses toward target PSA within the working range of 0.01–50 ng mL –1 at a low detection limit of 1.5 pg mL –1 . Good reproducibility and accuracy are acquired for analysis of target PSA and human serum specimens relative to the commercial PSA ELISA kit. Importantly, our strategy provides a new horizon for photoelectrochemical in vitro diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.8b01825

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 348

Metadata

Authors
Lv, S., Zhang, K., Zeng, Y., & Tang, D.
Venue
Analytical Chemistry
Published
2018-05-18
Volume
90
Issue
11
Pages
7086-7093
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2804860268
Cited by
348
References
29
FWCI
13.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Double Photosystems-Based ‘Z-Scheme’ Photoelectrochemical Sensing Mode for Ultrasensitive Detection of Disease Biomarker Accompanying Three-Dimensional DNA Walker. https://app.cochat.ai/papers/10.1021/acs.analchem.8b01825
The paper
Lv, S., Zhang, K., Zeng, Y., & Tang, D. (2018). Double Photosystems-Based ‘Z-Scheme’ Photoelectrochemical Sensing Mode for Ultrasensitive Detection of Disease Biomarker Accompanying Three-Dimensional DNA Walker. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b01825

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.