The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Dual-Response Fluorescent Probe for the Detection of Viscosity and H2S and Its Application in Studying Their Cross-Talk Influence in Mitochondria
Abstract
Abstract Intracellular viscosity is an essential microenvironmental parameter and H2S is a critical gaseous signaling molecule, which are both related to various physiological processes. It is reported that the change of viscosity and an imbalance of H2S production in the mitochondria are both associated with overexpression of amyloid betapeptide (Aβ), which is thought to play a central role in the pathogenesis of Alzheimer’s disease (AD). However, to our best knowledge, no fluorescent probe is found for dual detection of mitochondrial viscosity and H2S. Herein, a dual-response fluorescent probe (Mito-VS) is designed and synthesized to monitor the level of viscosity and H2S, respectively. Mito-VS itself is nonfluorescent due to a free intramolecular rotation between dimethylaniline and pyridine. After the increase of viscosity, the rotation is prohibited and an intense red fluorescence is released. Upon the addition of H2S, the probe can react with H2S to form compound 3 and a strong green fluorescence can be observed. Moreover, the probe possesses a good mitochondrion-targeting ability and is applied for imaging the change of viscosity on the red channel and visualizing the variation of exogenous and endogenous H2S concentration on the green channel in mitochondria. Most importantly, the probe is capable of studying the cross-talk influence of viscosity and H2S in mitochondria, which is very beneficial for knowing the pathogenesis of AD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minton, A. P. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.r100005200 · Cited by 1,474
Fluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Mitochondrial membrane fluidity and oxidative damage to mitochondrial DNA in aged and AD human brain
Mecocci, P., Beal, M. F., Cecchetti, R., Polidori, M. C., Cherubini, A., Chionne, F., Avellini, L., Romano, G., & Senin, U. (1997) · Molecular and Chemical Neuropathology · doi:10.1007/bf02815160 · Cited by 215
Cited by
Yin, J., Huang, L., Wu, L., Li, J., James, T. D., & Lin, W. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00645b · Cited by 549
Dual-locked spectroscopic probes for sensing and therapy
Wu, L., Huang, J., Pu, K., & James, T. D. (2021) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00277-2 · Cited by 328
Small Molecule Optical Probes for Detection of H2S in Water Samples: A Review
M, R., Kulkarni, R. M., & Sunil, D. (2024) · ACS Omega · doi:10.1021/acsomega.3c08573 · Cited by 38
Metadata
- Authors
- Li, S.-J., Li, Y.-F., Liu, H.-W., Zhou, D.-Y., Jiang, W.-L., Ou-Yang, J., & Li, C.-Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-07-05
- Volume
- 90
- Issue
- 15
- Pages
- 9418-9425
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2878579316
- Cited by
- 217
- References
- 3
- FWCI
- 10.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Dual-Response Fluorescent Probe for the Detection of Viscosity and H2S and Its Application in Studying Their Cross-Talk Influence in Mitochondria. https://app.cochat.ai/papers/10.1021/acs.analchem.8b02068
- The paper
- Li, S.-J., Li, Y.-F., Liu, H.-W., Zhou, D.-Y., Jiang, W.-L., Ou-Yang, J., & Li, C.-Y. (2018). A Dual-Response Fluorescent Probe for the Detection of Viscosity and H2S and Its Application in Studying Their Cross-Talk Influence in Mitochondria. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b02068
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.