The DOI matches its Crossref record.
Nucleic Acid-Functionalized Metal–Organic Framework-Based Homogeneous Electrochemical Biosensor for Simultaneous Detection of Multiple Tumor Biomarkers
Abstract
Simultaneous detection of multiple tumor biomarkers is in great demand for early and accurate cancer diagnosis. A homogeneous electrochemical biosensor has been proven to possess high sensitivity, but achieving simultaneous detection of multiple tumor biomarkers is still a challenge. Herein, we develop a novel homogeneous electrochemical biosensor for simultaneous detection of multiple tumor biomarkers based on the functionalized metal–organic frameworks (MOFs). The functionalized MOFs were prepared by using porous UIO-66-NH 2 as nanocontainer to load electroactive dyes and dsDNA as a gatekeeper to cap MOFs. In this context, two functionalized MOFs (MB@UIO and TMB@UIO) were fabricated and applied to simultaneous detection of let-7a and miRNA-21, used as the proof-of-concept analytes. The recognition and hybridization of P X with target miRNAs impel the generation of RNA–DNA complexes, which separated from MOFs and allowed the electroactive dyes to be released. In comparison with the case when target miRNAs are absent, two stronger signals are recorded, and dependent on target miRNA concentrations. Thus, simultaneous detection of let-7a and minRNA-21 is achieved, with detection limits down to 3.6 and 8.2 fM, respectively, comparable or lower than those of reported strategies that concentrated on single miRNA detection. Moreover, the proposed biosensor has also been successfully applied for simultaneous detection of target miRNAs spiked in serum samples. Therefore, the proposed strategy was expected to provide more information for early and accurate cancer diagnosis and was an useful application in disease diagnosis and clinical biomedicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Perovskite-SrTiO3/TiO2/PDA as photoelectrochemical glucose biosensor
Wang, Y., Yin, L., Wu, J., Li, N., He, N., Zhao, H., Wu, Q., & Li, X. (2021) · Ceramics International · doi:10.1016/j.ceramint.2021.07.152 · Cited by 24
Wang, W., Wang, Q., Xie, H., Wu, D., & Gan, N. (2021) · Talanta · doi:10.1016/j.talanta.2020.121456 · Cited by 21
Metadata
- Authors
- Chang, J., Wang, X., Wang, J., Li, H., & Li, F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-13
- Volume
- 91
- Issue
- 5
- Pages
- 3604-3610
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2912829358
- Cited by
- 469
- References
- 0
- FWCI
- 20.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nucleic Acid-Functionalized Metal–Organic Framework-Based Homogeneous Electrochemical Biosensor for Simultaneous Detection of Multiple Tumor Biomarkers. https://app.cochat.ai/papers/10.1021/acs.analchem.8b05599
- The paper
- Chang, J., Wang, X., Wang, J., Li, H., & Li, F. (2019). Nucleic Acid-Functionalized Metal–Organic Framework-Based Homogeneous Electrochemical Biosensor for Simultaneous Detection of Multiple Tumor Biomarkers. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b05599
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.