Development of a New Tandem Ion Exchange and Size Exclusion Chromatography Method To Monitor Vaccine Particle Titer in Cell Culture Media
Open accessAbstract
A new tandem chromatography method was developed to directly measure the titers of various vaccine candidate molecules in cell culture without a prior purification step. The method utilized a strong anion exchange chromatography (IEC) column in tandem with a size exclusion chromatography (SEC) column to efficiently separate the nanoparticle and virus-like particle (VLP) vaccine molecules from host cell proteins and other components in the cell culture media. The dual (charge and hydrodynamic size) separation mode was deemed necessary to achieve good separation of the vaccine product for quantitation. The method development and quality assessment illustrated herein was focused on the influenza vaccine candidate H1ssF, a hemagglutinin (group 1) stabilized stem molecule fused to ferritin to form nanoparticles. This newly established method was then successfully applied to several vaccine candidate developmental projects, such as the hemagglutinin-ferritin (HAF) nanoparticle and encephalitic alphavirus VLP-based vaccines. This IEC-SEC strategy was established as a platform approach for direct titer measurement of novel vaccine molecules in cell culture.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ion-exchange chromatography is a promising purification method that purifies vaccine process products using physical methods without adding exogenous products.
“Previous research has confirmed that ion-exchange chromatography is a promising purification method. It purifies vaccine process products using physical methods without adding exogenous products.”
From Evaluation of the Efficacy of the Vaccine Production Process in Removing Residual Host Cell DNA from the Vero Cell Rabies Vaccine (2024) · cites this paper as [27]
The Abstract (page not provided) describes ion-exchange chromatography combined with size-exclusion chromatography separating vaccine particles from cell-culture components. But the method is for analytical titer measurement without prior purification, not a vaccine-product purification process. The Materials and Methods describe buffers and salt used in the assay; the paper does not establish the claim that purification occurs without adding exogenous products. (LLM, conf=0.88)
Experimental — accuracy not yet measuredShaddeau et al. used tandem ion-exchange and size-exclusion chromatography to separate vaccine components from host cell proteins and other components in cell media to detect vaccine titres.
“Shaddeau et al. used tandem ion-exchange and size-exclusion chromatography to separate vaccine components from host cell proteins and other components in cell media to detect vaccine titres [27].”
From Evaluation of the Efficacy of the Vaccine Production Process in Removing Residual Host Cell DNA from the Vero Cell Rabies Vaccine (2024) · cites this paper as [27]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 18
- [1]Settembre EC; Dormitzer PR; Rappuoli R Hum. Vaccines Immunother 2014, 10, 600– 604. PMC4130286 24378716
- [2]Poland GA; Rottinghaus ST; Jacobson RM Vaccine 2001, 19, 2216– 2220. 11257336
- [3]Wolfe DN; Heppner DG; Gardner SN; Jaing C; Dupuy LC; Schmaljohn CS; Carlton K Am. J. Trop. Med. Hyg 2014, 91, 442– 450. 24842880 PMC4155543
- [4]Yassine HM; Boyington JC; McTamney PM; Wei CJ; Kanekiyo M; Kong WP; Gallagher JR; Wang L; Zhang Y; Joyce MG; Lingwood D; Moin SM; Andersen H; Okuno Y; Rao SS; Harris AK; Kwong PD; Mascola JR; Nabel GJ; Graham BS Nat. Med 2015, 21, 1065– 1070. 26301691
- [5]Kanekiyo M; Wei CJ; Yassine HM; McTamney PM; Boyington JC; Whittle JR; Rao SS; Kong WP; Wang L; Nabel GJ Nature 2013, 499, 102– 106. 23698367 PMC8312026
- [6]Impagliazzo A; Milder F; Kuipers H; Wagner MV; Zhu X; Hoffman RMB; van Meersbergen R; Huizingh J; Wanningen P; Verspuij J; de Man M; Ding Z; Apetri A; Kükrer B; Sneekes-Vriese E; Tomkiewicz D; Laursen NS; Lee PS; Zakrzewska A; Dekking L; Science 2015, 349, 1301– 1306. 26303961
- [7]Thompson CM; Petiot E; Mullick A; Aucoin MG; Henry O; Kamen AA BMC Biotechnol. 2015, 15, 31. 25981500 PMC4432999
- [8]Carvalho SB; Moleirinho MG; Wheatley D; Welsh J; Gantier R; Alves PM; Peixoto C; Carrondo MJT Biotechnol. J 2017, 12, 1700031. 28514082
- [9]Toprani VM; Cheng Y; Wahome N; Khasa H; Kueltzo LA; Schwartz RM; Middaugh CR; Joshi SB; Volkin DB J. Pharm. Sci 2018, 107, 2544– 2558. 29883665
- [10]Gollapudi D; Wycuff DL; Schwartz RM; Cooper JW; Cheng K Electrophoresis 2017, 38, 2610– 2621. 28842921
- [11]Xu D; Marchionni K; Hu Y; Zhang W; Sosic Z. J. Pharm. Biomed. Anal 2017, 145, 10– 15. 28645016
- [12]Thompson CM; Petiot E; Lennaertz A; Henry O; Kamen AA Virol. J 2013, 10, 141– 141. 23642219 PMC3655918
- [13]Vajda J; Weber D; Brekel D; Hundt B; Müller EJ Chromatogr. A 2016, 1465, 117– 125. 27578410
- [14]Baker KN; Rendall MH; Patel A; Boyd P; Hoare M; Freedman RB; James DC Trends Biotechnol. 2002, 20, 149– 156. 11906746
- [15]Shytuhina A; Pristatsky P; He J; Casimiro DR; Schwartz RM; Hoang VM; Ha S. J. Chromatogr. A 2014, 1364, 192– 197. 25234500 PMC4189818
- [16]Transfiguracion J; Manceur AP; Petiot E; Thompson CM; Kamen AA Vaccine 2015, 33, 78– 84. 25448111
- [17]Ladd Effio C; Oelmeier SA; Hubbuch J Vaccine 2016, 34, 1259– 1267. 26845741
- [18]Kapteyn JC; Saidi MD; Dijkstra R; Kars C; Tjon JCMSK; Weverling GJ; de Vocht ML; Kompier R; van Montfort BA; Guichoux J-Y; Goudsmit J; Lagerwerf FM Vaccine 2006, 24, 3137– 3144. 16490287
Cited by
Sorted by citations
Li, J., Pan, R., Yue, F., Gao, T., Wu, X., Shi, L., Wang, Y., Zhao, D., Lan, Z., Chen, H., et al. (2024) · Vaccines · doi:10.3390/vaccines12121379 · Cited by 8 · see citing works
- Authors
- Shaddeau, A. W., Schneck, N. A., Li, Y., Ivleva, V. B., Arnold, F. J., Cooper, J. W., & Lei, Q. P.
- Affiliations
- National Institutes of Health (US)
- Corresponding author
- Schneck, Nicole A.
- Lei, Q. Paula
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-04-29
- Volume
- 91
- Issue
- 10
- Pages
- 6430-6434
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- PMC
- PMC11040568
- OpenAlex
- W2942736834
- Cited by
- 12
- References
- 0
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 1
- FWCI
- 0.58
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Division of Intramural Research, National Institute of Allergy and Infectious Diseases
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
- Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- tandem chromatography, anion exchange chromatography, size exclusion chromatography, cell culture media, virus-like particles, nanoparticle vaccine, influenza vaccination
- MeSH terms
- Animals, Cell Line, Chromatography, Gel, Chromatography, Ion Exchange, Culture Media, Mammals, Particle Size, Vaccines
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review