The DOI matches its Crossref record; 51 of the 53 references it cites were found in a registry or an index.
More than a Liquid Junction: Effect of Stirring, Flow Rate, and Inward and Outward Electrolyte Diffusion on Reference Electrodes with Salt Bridges Contained in Nanoporous Glass
Abstract
The Henderson equation is usually used to calculate liquid-junction potentials between miscible electrolyte solutions. However, the potentials of reference electrodes that comprise an electrolyte-filled nanoporous glass frit may also be affected by charge screening. As reported previously, when the Debye length approaches or surpasses the glass pore diameter, reference potentials depend on the composition of the bridge electrolyte, the pore size of the frit, and the concentration of electrolyte in the sample. We report here that stirring of samples may alter the reference potential as it affects the electrolyte concentration in the section of the nanoporous glass frit that is facing the sample solution. When the flow rate of bridge electrolyte into the sample is small, convective mass transport of sample into the nanoporous frit occurs. The depth of penetration into the frit is only a few nanometers but, despite the use of concentrated salt bridges, this is enough to affect the extent of electrostatic screening when samples of low ionic strength are measured. Mixing of sample and salt bridge solutions-and in particular penetration of sample components into the frit-was optically monitored by observation of a deeply colored Fe[(SCN)(H2O)5]2+ complex that formed in situ exclusively in the region where the sample and salt bridge mixed. Importantly, because flow through nanoporous frits is very slow, mass transport through these frits is dominated by diffusion. Consequently, over…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Electrochemical methods, fundamentals and applications
Aikens, D. A. (1983) · Journal of Chemical Education · doi:10.1021/ed060pa25.1 · Cited by 3,139
Zimm, B. H. (1956) · The Journal of Chemical Physics · doi:10.1063/1.1742462 · Cited by 2,567
Van Dyke, M., & Widnall, S. (1983) · Journal of Applied Mechanics · doi:10.1115/1.3167071 · Cited by 1,655
The Intrinsic Viscosities and Diffusion Constants of Flexible Macromolecules in Solution
Kirkwood, J. G., & Riseman, J. (1948) · The Journal of Chemical Physics · doi:10.1063/1.1746947 · Cited by 1,562
Solvent Structure, Dynamics, and Ion Mobility in Aqueous Solutions at 25 °C
Koneshan, S., Rasaiah, J. C., Lynden-Bell, R. M., & Lee, S. H. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp980642x · Cited by 965
The Principles of Ion-Selective Electrodes and of Membrane Transport
(1981) · Studies in Analytical Chemistry · doi:10.1016/c2009-0-14175-2 · Cited by 650
Rational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Self-citationMeier, P. C. (1982) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95397-8 · Cited by 417
Lifetime of neutral carrier based ion-selective liquid-membrane electrodes
Oesch, U., & Simon, W. (1980) · Analytical Chemistry · doi:10.1021/ac50054a024 · Cited by 363
Handbook of Reference Electrodes
(2013) · Springer eBooks · doi:10.1007/978-3-642-36188-3 · Cited by 358
(1991) · Springer eBooks · doi:10.1007/978-94-011-3274-9 · Cited by 316
The Structure of Ferric Thiocyanate and its Dissociation in Aqueous Solution
Bent, H. E., & French, C. L. (1941) · Journal of the American Chemical Society · doi:10.1021/ja01847a059 · Cited by 316
The principles of ion-selective electrodes and of membrane transport
Thomas, J. D. R. (1982) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(82)88012-6 · Cited by 276
Visualization of Separating Stokes Flows
Taneda, S. (1979) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.46.1935 · Cited by 260
The phase-boundary potential model
Bakker, E., Bühlmann, P., & Pretsch, E. (2003) · Talanta · doi:10.1016/j.talanta.2003.10.006 · Cited by 258
Self-citationStokes flow in arbitrary two-dimensional domains: shear flow over ridges and cavities
Higdon, J. J. L. (1985) · Journal of Fluid Mechanics · doi:10.1017/s0022112085003172 · Cited by 214
Electrostatic-Gated Transport in Chemically Modified Glass Nanopore Electrodes
Wang, G., Zhang, B., Wayment, J. R., Harris, J. M., & White, H. S. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061357r · Cited by 200
Voltage-Rectified Current and Fluid Flow in Conical Nanopores
Lan, W.-J., Edwards, M. A., Luo, L., Perera, R. T., Wu, X., Martin, C. R., & White, H. S. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00395 · Cited by 176
Guinovart, T., Crespo, G. A., Rius, F. X., & Andrade, F. J. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.02.028 · Cited by 167
Self-diffusion of a molecule in porous Vycor glass
Dozier, W. D., Drake, J. M., & Klafter, J. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.197 · Cited by 166
Theoretical treatment of the selectivity and detection limit of silver compound membrane electrodes
Morf, W. E., Kahr, G., & Simon, W. (1974) · Analytical Chemistry · doi:10.1021/ac60347a014 · Cited by 137
Reference electrode with free-flowing free-diffusion liquid junction
Dohner, R. E., Wegmann, D., Morf, W. E., & Simon, W. (1986) · Analytical Chemistry · doi:10.1021/ac00125a053 · Cited by 130
New Class of Ag/AgCl Electrodes Based on Hydrophobic Ionic Liquid Saturated with AgCl
Kakiuchi, T., Yoshimatsu, T., & Nishi, N. (2007) · Analytical Chemistry · doi:10.1021/ac070820v · Cited by 125
Low Reynolds number flow over cavities
Shen, C., & Floryan, J. M. (1985) · The Physics of Fluids · doi:10.1063/1.865366 · Cited by 119
Paper-based electroanalytical devices with an integrated, stable reference electrode
Lan, W.-J., Maxwell, E. J., Parolo, C., Bwambok, D. K., Subramaniam, A. B., & Whitesides, G. M. (2013) · Lab on a Chip · doi:10.1039/c3lc50771h · Cited by 111
Electrochemistry: The Basics, With Examples
Lefrou, C., Fabry, P., & Poignet, J.-C. (2012) · Springer eBooks · doi:10.1007/978-3-642-30250-3 · Cited by 111
Chemically Modified Opals as Thin Permselective Nanoporous Membranes
Newton, M. R., Bohaty, A. K., White, H. S., & Zharov, I. (2005) · Journal of the American Chemical Society · doi:10.1021/ja043275d · Cited by 95
All-solid-state reference electrodes based on conducting polymers
Kisiel, A., Marcisz, H., Michalska, A., & Maksymiuk, K. (2005) · The Analyst · doi:10.1039/b510868c · Cited by 84
A New Salt Bridge Based on the Hydrophobic Room-Temperature Molten Salt
Kakiuchi, T., & Yoshimatsu, T. (2006) · Bulletin of the Chemical Society of Japan · doi:10.1246/bcsj.79.1017 · Cited by 78
Ionic Liquid‐Based, Liquid‐Junction‐Free Reference Electrode
Cicmil, D., Anastasova, S., Kavanagh, A., Diamond, D., Mattinen, U., Bobacka, J., Lewenstam, A., & Radu, A. (2011) · Electroanalysis · doi:10.1002/elan.201100137 · Cited by 73
Calculation of liquid-junction potentials and membrane potentials on the basis of the Planck theory
Morf, W. E. (1977) · Analytical Chemistry · doi:10.1021/ac50014a035 · Cited by 71
Mousavi, M. P. S., Saba, S. A., Anderson, E. L., Hillmyer, M. A., & Bühlmann, P. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02025 · Cited by 71
Self-citationZhang, T., Lai, C., Fierke, M. A., Stein, A., & Bühlmann, P. (2012) · Analytical Chemistry · doi:10.1021/ac3011507 · Cited by 70
Self-citationCan Calibration-Free Sensors Be Realized?
Bakker, E. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00247 · Cited by 63
Diffusion of Water and Electrolytes in Mesoporous Silica with a Wide Range of Pore Sizes
Martínez-Casillas, D. C., Longinotti, M. P., Bruno, M. M., Chávez, F. V., Acosta, R. H., & Corti, H. R. (2018) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.7b11555 · Cited by 61
Mousavi, M. P. S., & Bühlmann, P. (2013) · Analytical Chemistry · doi:10.1021/ac402170u · Cited by 55
Self-citationCalculation of liquid junction potentials
Harper, H. W. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100255a022 · Cited by 53
Environmental water analysis with membrane electrodes
Cuartero, M., & Bakker, E. (2017) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2017.06.010 · Cited by 52
Chopade, S. A., Anderson, E. L., Schmidt, P. W., Lodge, T. P., Hillmyer, M. A., & Bühlmann, P. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00512 · Cited by 43
Self-citationIntroduction to polymer chemistry
(2007) · Choice Reviews Online · doi:10.5860/choice.44-5651 · Cited by 42
Zou, X. U., Chen, L. D., Lai, C., & Bühlmann, P. (2014) · Electroanalysis · doi:10.1002/elan.201400274 · Cited by 41
Self-citationOptically Transparent Thin-Film Electrode Chip for Spectroelectrochemical Sensing
Branch, S. D., Lines, A. M., Lynch, J., Bello, J. M., Heineman, W. R., & Bryan, S. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00258 · Cited by 35
Slow Viscous Flow Past a Cavity
Takematsu, M. (1966) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.21.1816 · Cited by 31
Local Mass Transport in Two-Dimensional Cavities in Laminar Shear Flow
Georgiadou, M., Mohr, R., & Alkire, R. C. (2000) · Journal of The Electrochemical Society · doi:10.1149/1.1393642 · Cited by 25
Carano, M., Colonna, B., Echegoyen, L. A., Derf, F. L., Levillain, E., & Sallé, M. (2003) · Supramolecular chemistry · doi:10.1080/106102702100041456 · Cited by 10
Iron(III) Ion Adsorption on Macroporous Glass
Kuznetsova, A. S., Volkova, A. V., Ermakova, L. E., & Antropova, T. V. (2018) · Glass Physics and Chemistry · doi:10.1134/s1087659618010078 · Cited by 9
A pressure- and flow-insensitive reference electrode liquid junction
Crandall, E. D., & DeLong, J. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.41.1.125 · Cited by 7
Victoria, L., Ortega, M. G., & Ibáñez, J. A. (1990) · Journal of Chemical Education · doi:10.1021/ed067p179 · Cited by 6
Liquid junction potential calculations.
Gorman, M., & Murphy, S. M. C. (1949) · Journal of Chemical Education · doi:10.1021/ed026p579 · Cited by 6
A Stable Ultra Low Flow Reference Electrode Using a Nanochannel Glass Array Junction
Gao, F. G., Broadley, S., Chen, T.-Y., Payne, P. M., & Silverman, H. P. (2006) · ECS Transactions · doi:10.1149/1.2209340 · Cited by 5
Research works printed but not linked: 2
- Maurer, O.; Thieme, R. Apparatus for producing a pressure on the electrolytes in an electrode. German Pat.DE 1,233,172, Jan. 26, 1967.
- Helfferich F. G., 1962, Ion exchange
Cited by
Zdrachek, E., & Bakker, E. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04681 · Cited by 338
Zdrachek, E., & Bakker, E. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04249 · Cited by 201
Recent progress in the development of improved reference electrodes for electrochemistry
Troudt, B. K., Rousseau, C. R., Dong, X. I. N., Anderson, E. L., & Bühlmann, P. (2021) · Analytical Sciences · doi:10.2116/analsci.21sar11 · Cited by 80
Self-citationReconfiguration of organic electrochemical transistors for high-accuracy potentiometric sensing
Salvigni, L., Nayak, P. D., Koklu, A., Arcangeli, D., Uribe, J., Hama, A., Silva, R. K. S., Castillo, T. C. H., Griggs, S., Marks, A., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-50792-1 · Cited by 54
On the mechanism of the bipolar reference electrode
Walker, N. L., & Dick, J. E. (2023) · The Analyst · doi:10.1039/d3an00107e · Cited by 20
Metadata
- Authors
- Anderson, E. L., Lodge, T. P., Gopinath, T., Veglia, G., & Bühlmann, P.
- Affiliations
- University of Minnesota (US)
- Corresponding author
- Bühlmann, Philippe
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-05-23
- Volume
- 91
- Issue
- 12
- Pages
- 7698-7704
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2944826621
- Semantic Scholar
- 259705f586e35a5436613ac08a2825f0a65e6d10
- Cited by
- 17
- References
- 53
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 5 · 2021: 3 · 2020: 2 · 2019: 1
- FWCI
- 0.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Division of Chemistry (CHE-1748148)
- Graduate School, University of Minnesota
- American Chemical Society
- University of Minnesota
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Electrostatics and Colloid Interactions
- Keywords
- reference electrode, salt bridges, liquid junction potential, Henderson equation, electrostatic screening, Debye length, electrolyte diffusion, convective mass transfer, stirring effects, flow rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.