The DOI matches its Crossref record.
Plasmonic Au–Ag Janus Nanoparticle Engineered Ratiometric Surface-Enhanced Raman Scattering Aptasensor for Ochratoxin A Detection
Abstract
Ochratoxin A (OTA), a toxic mycotoxin, poses severe risks to environment and human health. Herein, we develop a ratiometric surface-enhanced Raman scattering (SERS) aptasensor based on internal standard (IS) methods for the sensitive and reproducible quantitative detection of OTA. Au-Ag Janus nanoparticles (NPs) are successfully synthesized under the guidance of 2-mercaptobenzoimidazole-5-carboxylic acid (MBIA), which possesses intrinsic Raman signals, thus no additional modification with a Raman reporter on NPs is required. In addition, Au-Ag Janus NPs exhibit amplified and stable SERS activity. MXenes nanosheets generate a unique and stable Raman signal, making them an ideal IS for quantitative Raman analysis. In principle, Au-Ag Janus NPs are assembled with MXenes nanosheets depending on hydrogen bond and the chelation interaction between MXenes nanosheets and OTA aptamers. In the presence of OTA, Au-Ag Janus NPs are dissociated from MXenes nanosheets due to the formation of aptamer/OTA complex, leading to the attenuation of Raman signal of Au-Ag Janus NPs, and meanwhile, the signal of MXenes nanosheets remain constant. Quantitatively, upon correction by the IS Raman signals, sensitive and quantitative detection can be achieved with the limit of detection (LOD) of 1.28 pM for OTA. Our results suggest that this ratiometric SERS aptasensor is a powerful tool which shows great promise for applications in complex systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Janus Nanoparticles: From Fabrication to (Bio)Applications
Zhang, X., Fu, Q., Duan, H., Song, J., & Yang, H. (2021) · ACS Nano · doi:10.1021/acsnano.1c01146 · Cited by 286
Nguyen, D. N., Phu, T. K. C., Kim, J., Hong, W. T., Kim, J., Roh, S. H., Park, H. S., Chung, C., Choe, W., Shin, H., et al. (2022) · Small · doi:10.1002/smll.202204797 · Cited by 46
Metadata
- Authors
- Zheng, F., Ke, W., Shi, L., Liu, H., & Zhao, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-08-19
- Volume
- 91
- Issue
- 18
- Pages
- 11812-11820
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2969867324
- Cited by
- 191
- References
- 0
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasmonic Au–Ag Janus Nanoparticle Engineered Ratiometric Surface-Enhanced Raman Scattering Aptasensor for Ochratoxin A Detection. https://app.cochat.ai/papers/10.1021/acs.analchem.9b02469
- The paper
- Zheng, F., Ke, W., Shi, L., Liu, H., & Zhao, Y. (2019). Plasmonic Au–Ag Janus Nanoparticle Engineered Ratiometric Surface-Enhanced Raman Scattering Aptasensor for Ochratoxin A Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.9b02469
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.