Sensitive Fluorescent Sensor for Hydrogen Sulfide in Rat Brain Microdialysis via CsPbBr3 Quantum Dots
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The instability and insolubility of perovskite quantum dots in aqueous solution prohibit applications in polar solvents. As a highly toxic gas pollutant and also an endogenous gaseous signaling molecule existing in a variety of physiological processes, hydrogen sulfide (H 2 S), with high selectivity and high specificity, detection is of great significance. In this study, a simple device has been designed to separate H 2 S from aqueous solution and CsPbBr 3 quantum dots (CsPbBr 3 QDs) have been used as the detection probe to develop a novel fluorescent sensor for rapid H 2 S detection. The addition of hydrogen sulfide to the phosphoric acid solution results in the escape of H 2 S from the aqueous sample and hence it passing into the n -hexane solution containing CsPbBr 3 QDs, resulting in the quenching of the fluorescence of CsPbBr 3 QDs. The fluorescence intensity of the system has a linear relationship with the concentration of H 2 S in the range of 0–100 μM with the detection limit of 0.18 μM. The proposed system has been applied to detection of H 2 S in rat brain microdialysate with satisfying results. The potential mechanism regarding the quenching of fluorescence from CsPbBr 3 QDs by H 2 S has been studied as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
H 2 S as a Physiologic Vasorelaxant: Hypertension in Mice with Deletion of Cystathionine γ-Lyase
Yang, G., Wu, L., Jiang, B., Yang, W., Qi, J., Cao, K., Meng, Q., Mustafa, A. K., Mu, W., Zhang, S., et al. (2008) · Science · doi:10.1126/science.1162667 · Cited by 2,310
Wang, Y., Zhu, Y., Huang, J., Cai, J., Zhu, J., Yang, X., Shen, J., & Li, C. (2017) · Nanoscale Horizons · doi:10.1039/c7nh00057j · Cited by 93
Visual and sensitive fluorescent sensing for ultratrace mercury ions by perovskite quantum dots
Lu, L.-Q., Tan, T., Tian, X.-K., Li, Y., & Deng, P. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.07.014 · Cited by 89
Cited by
Review on Sensing Applications of Perovskite Nanomaterials
Shellaiah, M., & Sun, K. W. (2020) · Chemosensors · doi:10.3390/chemosensors8030055 · Cited by 227
Perovskite materials for sensing applications: Recent advances and challenges
Bui, T. H., & Shin, J. H. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.108924 · Cited by 95
Shan, H., Xuan, W., Li, Z., Hu, D., Gu, X., & Huang, S. (2022) · ACS Applied Nano Materials · doi:10.1021/acsanm.2c00791 · Cited by 62
Li, G., She, C., Zhang, Y., Li, H., Liu, S., Yue, F., Jing, C., Cheng, Y., & Chu, J. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128918 · Cited by 60
Recent progress of gas sensors based on perovskites
Wei, C., Guo, Z., Wang, H., Zhang, S., Hao, D., & Huang, J. (2025) · Materials Horizons · doi:10.1039/d4mh01306a · Cited by 38
Metadata
- Authors
- Chen, C., Cai, Q., Luo, F., Dong, N., Guo, L., Qiu, B., & Lin, Z.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-11-22
- Volume
- 91
- Issue
- 24
- Pages
- 15915-15921
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2991155094
- Cited by
- 116
- References
- 3
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.