CoChat

Sensitive Fluorescent Sensor for Hydrogen Sulfide in Rat Brain Microdialysis via CsPbBr3 Quantum Dots

Chen, Chaoqun, Cai, Qing, Luo, Fang, Dong, Nuo, Guo, Longhua, Qiu, Bin, Lin, Zhenyu · 2019 · Analytical Chemistry
Cited by 116

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The instability and insolubility of perovskite quantum dots in aqueous solution prohibit applications in polar solvents. As a highly toxic gas pollutant and also an endogenous gaseous signaling molecule existing in a variety of physiological processes, hydrogen sulfide (H 2 S), with high selectivity and high specificity, detection is of great significance. In this study, a simple device has been designed to separate H 2 S from aqueous solution and CsPbBr 3 quantum dots (CsPbBr 3 QDs) have been used as the detection probe to develop a novel fluorescent sensor for rapid H 2 S detection. The addition of hydrogen sulfide to the phosphoric acid solution results in the escape of H 2 S from the aqueous sample and hence it passing into the n -hexane solution containing CsPbBr 3 QDs, resulting in the quenching of the fluorescence of CsPbBr 3 QDs. The fluorescence intensity of the system has a linear relationship with the concentration of H 2 S in the range of 0–100 μM with the detection limit of 0.18 μM. The proposed system has been applied to detection of H 2 S in rat brain microdialysate with satisfying results. The potential mechanism regarding the quenching of fluorescence from CsPbBr 3 QDs by H 2 S has been studied as well.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.9b04387

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 116

Metadata

Authors
Chen, C., Cai, Q., Luo, F., Dong, N., Guo, L., Qiu, B., & Lin, Z.
Venue
Analytical Chemistry
Published
2019-11-22
Volume
91
Issue
24
Pages
15915-15921
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2991155094
Cited by
116
References
3
FWCI
3.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.