The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Boric Acid-Functionalized Lanthanide Metal–Organic Framework as a Fluorescence “Turn-on” Probe for Selective Monitoring of Hg2+ and CH3Hg+
Abstract
Mercury detection remains an important task because of its high toxicity. Herein a new dual-signal probe based on a boric acid (BA)-functionalized lanthanide metal–organic framework (BA-Eu-MOF) was developed for the detection of Hg 2+ and CH 3 Hg + ions for the first time. The BA-Eu-MOF was synthesized by coordination of Eu 3+ with 5-boronobezene-1, 3-dicarboxylic acid (5-bop) through a one-pot method. The 5-bop ligand not only acted as the “antenna” to sensitize the luminescence of Eu 3+ but also provided reaction sites for Hg 2+ and CH 3 Hg + . Owing to the electron-withdrawing effect of the BA group, the “antenna” effect of the ligand was passivating and the BA-Eu-MOF showed weak red emission in water. Upon addition of Hg 2+ or CH 3 Hg + into the system, a transmetalation reaction took place, i.e., BA groups were replaced by Hg 2+ or CH 3 Hg +; therefore, the “antenna” effect of the ligand was triggered, leading to the enhancement of red emission. As Hg 2+ or CH 3 Hg + concentration increased, the red emission was gradually enhanced, and the color change was also observed with the naked eye under 365 nm ultraviolet light. Owing to the porous characteristics and the surface effect of the MOF, as well as the unique transmetalation reaction between the BA group and Hg 2+ or CH 3 Hg +, the developed nanoprobe showed excellent characteristics for simultaneous detection of Hg 2+ and CH 3 Hg +, such as simple preparation, convenient operation, “turn-on” signal output, high sensitivity, and selectivity. The unique features of the BA-Eu-MOF make it an attractive probe for monitoring Hg 2+ and CH 3 Hg + .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The toxicology of mercury—current exposures and clinical manifestations
Clarkson, T. W., Magos, L., & Myers, G. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra022471 · Cited by 1,766
Cited by
Rare-Earth Doping in Nanostructured Inorganic Materials
Zheng, B., Fan, J., Chen, B., Qin, X., Wang, J., Wang, F., Deng, R., & Liu, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00644 · Cited by 1,204
Yan, B. (2021) · Inorganic Chemistry Frontiers · doi:10.1039/d0qi01153c · Cited by 278
Metadata
- Authors
- Wang, H., Wang, X., Liang, M., Chen, G., Kong, R.-M., Xia, L., & Qu, F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-01-30
- Volume
- 92
- Issue
- 4
- Pages
- 3366-3372
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W3003776818
- Cited by
- 222
- References
- 1
- FWCI
- 18.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Boric Acid-Functionalized Lanthanide Metal–Organic Framework as a Fluorescence “Turn-on” Probe for Selective Monitoring of Hg2+ and CH3Hg+. https://app.cochat.ai/papers/10.1021/acs.analchem.9b05410
- The paper
- Wang, H., Wang, X., Liang, M., Chen, G., Kong, R.-M., Xia, L., & Qu, F. (2020). A Boric Acid-Functionalized Lanthanide Metal–Organic Framework as a Fluorescence “Turn-on” Probe for Selective Monitoring of Hg2+ and CH3Hg+. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.9b05410
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.