CoChat

Matrix Coordination-Induced Electrochemiluminescence Enhancement of Tetraphenylethylene-Based Hafnium Metal–Organic Framework: An Electrochemiluminescence Chromophore for Ultrasensitive Electrochemiluminescence Sensor Construction

Huang, Wei, Hu, Gui-Bing, Yao, Li-Ying, Yang, Yang, Liang, Wen-Bin, Yuan, Ruo, Xiao, Dong-Rong · 2020 · Analytical Chemistry
Cited by 170

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Here, we discovered that rigidifying the tetraphenylethylene (TPE)-based ligand H 4 TCBPE (H 4 TCBPE = 1,1,2,2-tetra(4-carboxylbiphenyl)ethylene) into Hf-based metal–organic framework (Hf-TCBPE) could lead to a stronger electrochemiluminescence (ECL) emission in comparison to H 4 TCBPE aggregates and H 4 TCBPE monomers. Due to the lack of close-packed TCBPE chromophores in Hf-TCBPE, which was required for aggregation-induced ECL (AI-ECL) enhancement, we defined this unprecedented phenomenon as matrix coordination-induced ECL (MCI-ECL) enhancement. The strong ECL intensity of Hf-TCBPE not only originated from the fixation of the TCBPE ligand between Hf 6 clusters that restricted the intramolecular free motions of TCBPE and suppressed the nonradiative relaxation but also stemmed from the high porosity of Hf-TCBPE that rendered both internal and external TCBPE chromophores able to be excited. Considering the unique ECL characteristic of Hf-TCBPE, we combined the new ECL indicator of Hf-TCBPE as well as the phosphate-terminal ferrocene (Fc)-labeled hairpin DNA (Fc-HP3) aptamer together as a signal probe (Hf-TCBPE/Fc-HP3), which was employed to construct a novel “off–on” ECL sensor for ultrasensitive mucin 1 (MUC1) detection with the assistance of the exonuclease III (Exo III)-assisted recycling amplification strategy. As expected, the ECL sensor displayed a desirable linear response range from 1 fg/mL to 1 ng/mL and the detection limit down to 0.49 fg/mL. The MCI-ECL enhancement demonstrated by the Hf-TCBPE developed a new and promising strategy to design and synthesize high-performance metal–organic framework (MOF)-based ECL materials for constructing ultrasensitive ECL sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.9b05444

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 170

Metadata

Authors
Huang, W., Hu, G.-B., Yao, L.-Y., Yang, Y., Liang, W.-B., Yuan, R., & Xiao, D.-R.
Venue
Analytical Chemistry
Published
2020-01-22
Volume
92
Issue
4
Pages
3380-3387
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3001188061
Cited by
170
References
2
FWCI
7.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.