Role of Fluorophore Charge on the In Vivo Optical Imaging Properties of Near-Infrared Cyanine Dye/Monoclonal Antibody Conjugates
Open accessThe DOI matches its Crossref record.
Abstract
Near-infrared (NIR) fluorophores have several advantages over visible-light fluorophores, including superior light penetration in tissue and lower autofluorescence. We recently demonstrated that a new class of NIR cyanine dyes containing a novel C4'-O-alkyl linker exhibit greater chemical stability and excellent optical properties relative to existing C4'-O-aryl variants. We synthesized two NIR cyanine dyes with the same core structure but different indolenine substituents: FNIR-774 bearing four sulfonate groups and FNIR-Z-759 bearing a combination of two sulfonates and two quaternary ammonium cations, resulting in an anionic (-3) or monocationic (+1) charge, respectively. In this study, we compare the in vitro and in vivo optical imaging properties of monoclonal antibody (mAb) conjugates of FNIR-774 and FNIR-Z-759 with panitumumab (pan) at antibody-to-dye ratios of 1:2 or 1:5. Conjugates of both dyes demonstrated similar quenching capacity, stability, and brightness in target cells in vitro. However, FNIR-Z-759 conjugates showed significantly lower background in mice, resulting in higher tumor-to-background ratio. Thus, FNIR-Z-759 conjugates appear to have superior in vivo imaging characteristics compared with FNIR-774 conjugates, especially in the abdominal region, regardless of the dye-mAb ratio. These results suggest that zwitterionic cyanine dyes are a promising class of fluorophores for improving in vivo optical imaging with antibody-NIR dye conjugates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Supramolecular Luminescent Sensors
Mako, T. L., Racicot, J. M., & Levine, M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00260 · Cited by 735
Li, D., Schreiber, C. L., & Smith, B. D. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202004449 · Cited by 163
A chemically stable fluorescent marker of the ureter
Cha, J., Nani, R. R., Luciano, M. P., Kline, G., Broch, A., Kim, K., Namgoong, J.-M., Kulkarni, R. A., Meier, J. L., Kim, P., et al. (2018) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2018.02.040 · Cited by 59
Self-citation
Metadata
- Authors
- Sato, K., Gorka, A. P., Nagaya, T., Michie, M. S., Nani, R. R., Nakamura, Y., Coble, V. L., Vasalatiy, O. V., Swenson, R. E., Choyke, P. L., Schnermann, M. J., & Kobayashi, H.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-10-23
- Volume
- 27
- Issue
- 2
- Pages
- 404-413
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W2200426434
- Cited by
- 73
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Role of Fluorophore Charge on the In Vivo Optical Imaging Properties of Near-Infrared Cyanine Dye/Monoclonal Antibody Conjugates. https://app.cochat.ai/papers/10.1021/acs.bioconjchem.5b00492
- The paper
- Sato, K., Gorka, A. P., Nagaya, T., Michie, M. S., Nani, R. R., Nakamura, Y., Coble, V. L., Vasalatiy, O. V., Swenson, R. E., Choyke, P. L., Schnermann, M. J., & Kobayashi, H. (2016). Role of Fluorophore Charge on the In Vivo Optical Imaging Properties of Near-Infrared Cyanine Dye/Monoclonal Antibody Conjugates. Bioconjugate Chemistry. https://doi.org/10.1021/acs.bioconjchem.5b00492
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.