Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 182

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Measuring the Glass Transition Temperature of Conjugated Polymer Films with Ultraviolet–Visible Spectroscopy

Root, Samuel E., Alkhadra, Mohammad A., Rodriquez, Daniel, Printz, Adam D., Lipomi, Darren J. · 2017 · Chemistry of Materials

Abstract

The glass transition temperature ( T g ) of a conjugated polymer can be used to predict its morphological stability and mechanical properties. Despite the importance of this parameter in applications from organic solar cells to wearable electronics, it is not easy to measure. The T g is often too weak to detect using conventional differential scanning calorimetry (DSC). Alternative methods—e.g., variable temperature ellipsometry—require specialized equipment. This paper describes a technique for measuring the T g of thin films of semicrystalline conjugated polymers using only a hot plate and an ultraviolet–visible (UV–vis) spectrometer. UV–vis spectroscopy is used to measure changes in the absorption spectrum due to molecular-scale rearrangement of polymers when heated past T g, corresponding to the onset of the formation of photophysical aggregates. A deviation metric, defined as the sum of the squared deviation in absorbance between as-cast and annealed films, is used to quantify shifts in the absorption spectra. The glass transition is observed as a change in slope in a plot of the deviation metric versus temperature. To demonstrate the usefulness of this technique, a variety of semiconducting polymers are tested: P3BT, PBTTT-C14, F8BT, PDTSTPD, PTB7, PCDTBT, TQ1, and MEH-PPV. These polymers represent a range of solid-state morphologies, from highly ordered to predominantly amorphous. A successful measurement of T g depends on the ability of the polymer to form photophysical aggregates. The results obtained using this method for P3BT, PBTTT-C14, F8BT, and PDTSTPD are in agreement with values of T g that have been reported in the literature. Molecular dynamics simulations are used to show how the morphology evolves upon annealing: above the T g, an initially kinetically trapped morphology undergoes structural rearrangement to assume a more thermodynamically preferred structure. The temperature at which onset of this rearrangement occurs in the simulation is concomitant with the spectroscopically determined value of T g .

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.chemmater.7b00242

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 182

Metadata

Authors
Root, S. E., Alkhadra, M. A., Rodriquez, D., Printz, A. D., & Lipomi, D. J.
Venue
Chemistry of Materials
Published
2017-03-24
Volume
29
Issue
7
Pages
2646-2654
ISSN
  • 0897-4756 (ISSN-L)
  • 1520-5002
OpenAlex
W2600215323
Cited by
182
References
2
FWCI
3.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.