The DOI matches its Crossref record; 242 of the 242 references it cites were found in a registry or an index.
Vibrational Spectroscopy of Ionic Liquids
Abstract
Vibrational spectroscopy has continued use as a powerful tool to characterize ionic liquids since the literature on room temperature molten salts experienced the rapid increase in number of publications in the 1990's. In the past years, infrared (IR) and Raman spectroscopies have provided insights on ionic interactions and the resulting liquid structure in ionic liquids. A large body of information is now available concerning vibrational spectra of ionic liquids made of many different combinations of anions and cations, but reviews on this literature are scarce. This review is an attempt at filling this gap. Some basic care needed while recording IR or Raman spectra of ionic liquids is explained. We have reviewed the conceptual basis of theoretical frameworks which have been used to interpret vibrational spectra of ionic liquids, helping the reader to distinguish the scope of application of different methods of calculation. Vibrational frequencies observed in IR and Raman spectra of ionic liquids based on different anions and cations are discussed and eventual disagreements between different sources are critically reviewed. The aim is that the reader can use this information while assigning vibrational spectra of an ionic liquid containing another particular combination of anions and cations. Different applications of IR and Raman spectroscopies are given for both pure ionic liquids and solutions. Further issues addressed in this review are the intermolecular vibrations that are more directly probed by the low-frequency range of IR and Raman spectra and the applications of vibrational spectroscopy in studying phase transitions of ionic liquids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computer Simulation of Liquids
P, S., & J, K. (1988) · Journal of Molecular Liquids · doi:10.1016/0167-7322(88)80022-9 · Cited by 15,812
Kubo, R. (1957) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.12.570 · Cited by 9,441
The Hydrogen Bond in the Solid State
Steiner, T. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020104)41:1<48::aid-anie48>3.0.co;2-u · Cited by 6,247
An introduction to hydrogen bonding
(1998) · Choice Reviews Online · doi:10.5860/choice.35-3309 · Cited by 6,199
Solvents and Solvent Effects in Organic Chemistry
Reichardt, C. (2002) · Wiley eBooks · doi:10.1002/3527601791 · Cited by 5,789
Applications of ionic liquids in the chemical industry
Plechkova, N. V., & Seddon, K. R. (2008) · Chem. Soc. Rev. · doi:10.1039/b006677j · Cited by 5,686
Deacon, G. (1980) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(00)80455-5 · Cited by 5,123
Ionic Liquids--Solvents of the Future?
Rogers, R. D., & Seddon, K. R. (2003) · Science · doi:10.1126/science.1090313 · Cited by 4,130
Huddleston, J. G., Visser, A. E., Reichert, W. M., Willauer, H. D., Broker, G. A., & Rogers, R. D. (2001) · Green Chemistry · doi:10.1039/b103275p · Cited by 3,712
Handbook of Vibrational Spectroscopy
(2001) · Wiley eBooks · doi:10.1002/0470027320 · Cited by 2,986
Cited by
Lei, Z., Chen, B., Koo, Y.-M., & MacFarlane, D. R. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00246 · Cited by 1,460
The peculiar effect of water on ionic liquids and deep eutectic solvents
Ma, C., Laaksonen, A., Liu, C., Lu, X., & Ji, X. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00325d · Cited by 584
Metadata
- Authors
- Paschoal, V. H., Faria, L. F. O., & Ribeiro, M. C. C.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-01-04
- Volume
- 117
- Issue
- 10
- Pages
- 7053-7112
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2568469236
- Cited by
- 414
- References
- 242
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.