The DOI matches its Crossref record; 240 of the 240 references it cites were found in a registry or an index.
Three-Dimensional Localization of Single Molecules for Super-Resolution Imaging and Single-Particle Tracking
Open accessAbstract
Single-molecule super-resolution fluorescence microscopy and single-particle tracking are two imaging modalities that illuminate the properties of cells and materials on spatial scales down to tens of nanometers or with dynamical information about nanoscale particle motion in the millisecond range, respectively. These methods generally use wide-field microscopes and two-dimensional camera detectors to localize molecules to much higher precision than the diffraction limit. Given the limited total photons available from each single-molecule label, both modalities require careful mathematical analysis and image processing. Much more information can be obtained about the system under study by extending to three-dimensional (3D) single-molecule localization: without this capability, visualization of structures or motions extending in the axial direction can easily be missed or confused, compromising scientific understanding. A variety of methods for obtaining both 3D super-resolution images and 3D tracking information have been devised, each with their own strengths and weaknesses. These include imaging of multiple focal planes, point-spread-function engineering, and interferometric detection. These methods may be compared based on their ability to provide accurate and precise position information on single-molecule emitters with limited photons. To successfully apply and further develop these methods, it is essential to consider many practical concerns, including the effects of optical aberrations, field dependence in the imaging system, fluorophore labeling density, and registration between different color channels. Selected examples of 3D super-resolution imaging and tracking are described for illustration from a variety of biological contexts and with a variety of methods, demonstrating the power of 3D localization for understanding complex systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–240 of 240
Ram, S., Kim, D., Ober, R. J., & Ward, E. S. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.08.054 · Cited by 82
Fast compressed sensing analysis for super-resolution imaging using L1-homotopy
Babcock, H. P., Moffitt, J. R., Cao, Y., & Zhuang, X. (2013) · Optics Express · doi:10.1364/oe.21.028583 · Cited by 80
Backer, A. S., Backlund, M. P., von Diezmann, L., Sahl, S. J., & Moerner, W. E. (2014) · Applied Physics Letters · doi:10.1063/1.4876440 · Cited by 76
Self-citationResolving Single-Molecule Assembled Patterns with Superresolution Blink-Microscopy
Cordes, T., Strackharn, M., Ståhl, S., Summerer, W., Steinhauer, C., Forthmann, C., Puchner, E. M., Vogelsang, J., Gaub, H. E., & Tinnefeld, P. (2009) · Nano Letters · doi:10.1021/nl903730r · Cited by 76
A Stochastic Analysis of Performance Limits for Optical Microscopes
Ram, S., Ward, E. S., & Ober, R. J. (2006) · Multidimensional Systems and Signal Processing · doi:10.1007/s11045-005-6237-2 · Cited by 73
Isotropic 3D Nanoscopy based on single emitter switching
von Middendorff, C., Egner, A., Geisler, C., Hell, S. W., & Schönle, A. (2008) · Optics Express · doi:10.1364/oe.16.020774 · Cited by 72
Near-isotropic 3D optical nanoscopy with photon-limited chromophores
Tang, J., Akerboom, J., Vaziri, A., Looger, L. L., & Shank, C. V. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1004899107 · Cited by 70
Backlund, M. P., Joyner, R. P., Weis, K., & Moerner, W. E. (2014) · Molecular Biology of the Cell · doi:10.1091/mbc.e14-06-1127 · Cited by 69
Self-citationSingle-molecule orientation measurements with a quadrated pupil
Backer, A. S., Backlund, M. P., Lew, M. D., & Moerner, W. E. (2013) · Optics Letters · doi:10.1364/ol.38.001521 · Cited by 66
Self-citationUnveiling the Inner Workings of Live Bacteria Using Super-Resolution Microscopy
Tuson, H. H., & Biteen, J. S. (2014) · Analytical Chemistry · doi:10.1021/ac5041346 · Cited by 64
Lee, M. R., Williams, J. C., Twieg, R. J., Rao, J., & Moerner, W. E. (2012) · Chemical Science · doi:10.1039/c2sc21074f · Cited by 63
Self-citationAxial superresolution via multiangle TIRF microscopy with sequential imaging and photobleaching
Fu, Y., Winter, P. W., Rojas, R., Wang, V. C., McAuliffe, M., & Patterson, G. H. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1516715113 · Cited by 63
Improved single particle localization accuracy with dual objective multifocal plane microscopy
Ram, S., Prabhat, P., Ward, E. S., & Ober, R. J. (2009) · Optics Express · doi:10.1364/oe.17.006881 · Cited by 62
Lew, M. D., & Moerner, W. E. (2014) · Nano Letters · doi:10.1021/nl502914k · Cited by 62
Self-citationMolecules and Methods for Super-Resolution Imaging
Thompson, M. A., Biteen, J. S., Lord, S. J., Conley, N. R., & Moerner, W. E. (2010) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(10)75002-3 · Cited by 60
Self-citationWang, Y., Quan, T., Zeng, S., & Huang, Z. (2012) · Optics Express · doi:10.1364/oe.20.016039 · Cited by 59
Resolution improvement by 3D particle averaging in localization microscopy
Broeken, J., Johnson, H., Lidke, D. S., Liu, S., Nieuwenhuizen, R. P. J., Stallinga, S., Lidke, K. A., & Rieger, B. (2015) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/3/1/014003 · Cited by 57
Lee, H. D., Sahl, S. J., Lew, M. D., & Moerner, W. E. (2012) · Applied Physics Letters · doi:10.1063/1.3700446 · Cited by 52
Self-citationSingle-Molecule and Superresolution Imaging in Live Bacteria CellsPreprint
Biteen, J. S., & Moerner, W. E. (2010) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a000448 · Cited by 51
Self-citationMolecular Approaches to Chromatography Using Single Molecule Spectroscopy
Kisley, L., & Landes, C. F. (2014) · Analytical Chemistry · doi:10.1021/ac5039225 · Cited by 50
Single‐Molecule Super‐Resolution Light‐Sheet Microscopy
Hu, Y., Zimmerley, M., Li, Y., Watters, R., & Cang, H. (2014) · ChemPhysChem · doi:10.1002/cphc.201300732 · Cited by 48
David, Baddeley, ', M., et al. (2011) · 纳米研究:英文版 · Cited by 48
Simultaneous measurement of emission color and 3D position of single molecules
Smith, C., Huisman, M., Siemons, M. E., Grünwald, D., & Stallinga, S. (2016) · Optics Express · doi:10.1364/oe.24.004996 · Cited by 47
Three-dimensional super-resolution and localization of dense clusters of single molecules
Barsic, A. J., Grover, G., & Piestun, R. (2014) · Scientific Reports · doi:10.1038/srep05388 · Cited by 46
A common aberration with water‐immersion objective lenses
Arimoto, R., & Murray, J. M. (2004) · Journal of Microscopy · doi:10.1111/j.0022-2720.2004.01383.x · Cited by 45
Ultrahigh accuracy imaging modality for super-localization microscopy
Chao, J. W., Ram, S., Ward, E. S., & Ober, R. J. (2013) · Nature Methods · doi:10.1038/nmeth.2396 · Cited by 44
Friedrich, J., & Haarer, D. (1986) · Physics and chemistry of materials with low-dimensional structures. Series C, Molecular structures · doi:10.1007/978-94-009-4650-7_4 · Cited by 44
II Optical Spectroscopy of Single Molecules in Solids
Orrit, M., Bernard, J., Brown, R., & Lounis, B. (1996) · Progress in optics · doi:10.1016/s0079-6638(08)70528-6 · Cited by 42
Isotropic 3D Super Resolution Imaging with Self-Bending Point Spread Function
Jia, S., Vaughan, J. C., & Zhuang, X. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2012.11.3687 · Cited by 41
Chao, J. W., Ward, E. S., & Ober, R. J. (2011) · Multidimensional Systems and Signal Processing · doi:10.1007/s11045-011-0150-7 · Cited by 40
3D Particle Trajectories Observed by Orthogonal Tracking Microscopy
McMahon, M. D., Berglund, A. J., Carmichael, P. T., McClelland, J. J., & Liddle, J. A. (2009) · ACS Nano · doi:10.1021/nn8008036 · Cited by 39
Designing the focal plane spacing for multifocal plane microscopy
Tahmasbi, A., Ram, S., Chao, J. W., Abraham, A. V., Tang, F. W., Ward, E. S., & Ober, R. J. (2014) · Optics Express · doi:10.1364/oe.22.016706 · Cited by 34
Shuang, B., Wang, W., Shen, H., Tauzin, L. J., Flatebo, C., Chen, J., Moringo, N. A., Bishop, L. D. C., Kelly, K. F., & Landes, C. F. (2016) · Scientific Reports · doi:10.1038/srep30826 · Cited by 33
Optical tracking of nanoscale particles in microscale environments
Mathai, P. P., Liddle, J., & Stavis, S. M. (2016) · Applied Physics Reviews · doi:10.1063/1.4941675 · Cited by 31
Colocalization of Fluorescent Probes: Accurate and Precise Registration with Nanometer ResolutionPreprint
Churchman, L. S., & Spudich, J. A. (2012) · Cold Spring Harbor Protocols · doi:10.1101/pdb.top067918 · Cited by 27
Tahmasbi, A., Ward, E. S., & Ober, R. J. (2015) · Optics Express · doi:10.1364/oe.23.007630 · Cited by 22
Changes in single-molecule integrin dynamics linked to local cellular behavior
Jaqaman, K., Galbraith, J. A., Davidson, M. W., & Galbraith, C. G. (2016) · Molecular Biology of the Cell · doi:10.1091/mbc.e16-01-0018 · Cited by 20
Controlled bimolecular collisions allow sub-diffraction limited microscopy of lipid vesicles
Mei, E., Gao, F., & Hochstrasser, R. M. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b601670g · Cited by 12
(2012) · Springer eBooks · doi:10.1007/978-3-642-16712-6_100309 · Cited by 10
Erratum: Integrins β1 and β3 exhibit distinct dynamic nanoscale organizations inside focal adhesions
Rossier, O., Octeau, V., Sibarita, J., Leduc, C., Tessier, B., Nair, D. K., Gatterdam, V., Destaing, O., Albigès‐Rizo, C., Tampé, R., et al. (2012) · Nature Cell Biology · doi:10.1038/ncb2620 · Cited by 6
Cited by
Visualizing and discovering cellular structures with super-resolution microscopy
Sigal, Y. M., Zhou, R., & Zhuang, X. (2018) · Science · doi:10.1126/science.aau1044 · Cited by 718
Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
DeepSTORM3D: dense 3D localization microscopy and PSF design by deep learning
Nehme, E., Freedman, D., Gordon, R., Ferdman, B., Weiss, L. E., Alalouf, O., Naor, T., Orange, R., Michaeli, T., & Shechtman, Y. (2020) · Nature Methods · doi:10.1038/s41592-020-0853-5 · Cited by 311
Self-citationWasisto, H. S., Prades, J. D., Gülink, J., & Waag, A. (2019) · Applied Physics Reviews · doi:10.1063/1.5096322 · Cited by 309
Single-molecule fluorescence microscopy review: shedding new light on old problems
Shashkova, S., & Leake, M. C. (2017) · Bioscience Reports · doi:10.1042/bsr20170031 · Cited by 289
Metadata
- Authors
- von Diezmann, L., Shechtman, Y., & Moerner, W. E.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-02-02
- Volume
- 117
- Issue
- 11
- Pages
- 7244-7275
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2584476676
- Cited by
- 491
- References
- 240
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.