The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bringing High-Rate, CO2-Based Microbial Electrosynthesis Closer to Practical Implementation through Improved Electrode Design and Operating Conditions
Open accessAbstract
The enhancement of microbial electrosynthesis (MES) of acetate from CO2 to performance levels that could potentially support practical implementations of the technology must go through the optimization of key design and operating conditions. We report that higher proton availability drastically increases the acetate production rate, with pH 5.2 found to be optimal, which will likely suppress methanogenic activity without inhibitor addition. Applied cathode potential as low as -1.1 V versus SHE still achieved 99% of electron recovery in the form of acetate at a current density of around -200 A m(-2). These current densities are leading to an exceptional acetate production rate of up to 1330 g m(-2) day(-1) at pH 6.7. Using highly open macroporous reticulated vitreous carbon electrodes with macropore sizes of about 0.6 mm in diameter was found to be optimal for achieving a good balance between total surface area available for biofilm formation and effective mass transfer between the bulk liquid and the electrode and biofilm surface. Furthermore, we also successfully demonstrated the use of a synthetic biogas mixture as carbon dioxide source, yielding similarly high MES performance as pure CO2. This would allow this process to be used effectively for both biogas quality improvement and conversion of the available CO2 to acetate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nevin, K. P., Kim, B.-C., Glaven, R. H., Johnson, J. P., Woodard, T. L., Methé, B. A., DiDonato, R. J., Covalla, S. F., Franks, A. E., Liu, A., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005628 · Cited by 441
Cited by
Transformation technologies for CO2 utilisation: Current status, challenges and future prospects
Kamkeng, A. D. N., Wang, M., Hu, J., Du, W., & Qian, F. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.128138 · Cited by 475
Grim, R. G., Huang, Z., Guarnieri, M. T., Ferrell, J. R., Tao, L., & Schaidle, J. A. (2020) · Energy & Environmental Science · doi:10.1039/c9ee02410g · Cited by 454
Microbial electrosynthesis from CO2: forever a promise?
Prévoteau, A., Carvajal-Arroyo, J. M., Ganigué, R., & Rabaey, K. (2020) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2019.08.014 · Cited by 362
Bian, B., Bajracharya, S., Xu, J., Pant, D., & Saikaly, P. E. (2020) · Bioresource Technology · doi:10.1016/j.biortech.2020.122863 · Cited by 278
Carbon dioxide and organic waste valorization by microbial electrosynthesis and electro-fermentation
Jiang, Y., May, H. D., Lu, L., Liang, P., Huang, X., & Ren, Z. J. (2019) · Water Research · doi:10.1016/j.watres.2018.10.092 · Cited by 263
Metadata
- Authors
- Jourdin, L., Freguia, S., Flexer, V., & Keller, J.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-02-03
- Volume
- 50
- Issue
- 4
- Pages
- 1982-1989
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2268173306
- Cited by
- 179
- References
- 1
- FWCI
- 11.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.