Novel Process of Simultaneous Removal of Nitric Oxide and Sulfur Dioxide Using a Vacuum Ultraviolet (VUV)-Activated O2/H2O/H2O2 System in A Wet VUV–Spraying Reactor
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
A novel process for NO and SO 2 simultaneous removal using a vacuum ultraviolet (VUV, with 185 nm wavelength)-activated O 2 /H 2 O/H 2 O 2 system in a wet VUV–spraying reactor was developed. The influence of different process variables on NO and SO 2 removal was evaluated. Active species (O 3 and ·OH) and liquid products (SO 3 2–, NO 2 –, SO 4 2–, and NO 3 – ) were analyzed. The chemistry and routes of NO and SO 2 removal were investigated. The oxidation removal system exhibits excellent simultaneous removal capacity for NO and SO 2, and a maximum removal of 96.8% for NO and complete SO 2 removal were obtained under optimized conditions. SO 2 reaches 100% removal efficiency under most of test conditions. NO removal is obviously affected by several process variables. Increasing VUV power, H 2 O 2 concentration, solution pH, liquid-to-gas ratio, and O 2 concentration greatly enhances NO removal. Increasing NO and SO 2 concentration obviously reduces NO removal. Temperature has a dual impact on NO removal, which has an optimal temperature of 318 K. Sulfuric acid and nitric acid are the main removal products of NO and SO 2 . NO removals by oxidation of O 3, O·, and ·OH are the primary routes. NO removals by H 2 O 2 oxidation and VUV photolysis are the complementary routes. A potential scaled-up removal process was also proposed initially.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332
Removal of NO by photocatalytic processes
Lasek, J., Yu, Y.-H., & Wu, J. C. S. (2013) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2012.08.002 · Cited by 374
Photochemical Removal of Mercury from Flue Gas
Granite, E. J., & Pennline, H. W. (2002) · Industrial & Engineering Chemistry Research · doi:10.1021/ie020251b · Cited by 322
Simultaneous removal of NO and SO2 from coal-fired flue gas by UV/H2O2 advanced oxidation process
Liu, Y., Zhang, J., Sheng, C., Zhang, Y., & Liang, Z. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2010.07.009 · Cited by 257
Self-citationFormation and decay of peroxynitrous acid: a pulse radiolysis study
Loegager, T., & Sehested, K. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100127a016 · Cited by 201
Rate constants for some oxidations of S(IV) by radicals in aqueous solutions
Huie, R. E., & Neta, P. (1987) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(87)90113-2 · Cited by 186
Liu, Y., & Wang, Q. (2014) · Environmental Science & Technology · doi:10.1021/es501966h · Cited by 173
Self-citationA dual-use of DBD plasma for simultaneous NOx and SO2 removal from coal-combustion flue gas
Obradović, B. M., Sretenović, G. B., & Kuraica, M. M. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.10.043 · Cited by 163
Liu, Y., & Adewuyi, Y. G. (2016) · Process Safety and Environmental Protection · doi:10.1016/j.cherd.2016.06.024 · Cited by 157
Self-citationAdewuyi, Y. G., & Sakyi, N. Y. (2013) · Industrial & Engineering Chemistry Research · doi:10.1021/ie401649s · Cited by 154
Cited by
Wu, Z., Chen, C., Zhu, B.-Z., Huang, C.-H., An, T., Meng, F., & Fang, J. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b01212 · Cited by 203
Hydrated electron based decomposition of perfluorooctane sulfonate (PFOS) in the VUV/sulfite system
Gu, Y., Liu, T., Wang, H., Han, H., & Dong, W. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.197 · Cited by 173
Metadata
- Authors
- Liu, Y., Wang, Q., & Pan, J.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-11-10
- Volume
- 50
- Issue
- 23
- Pages
- 12966-12975
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2546318933
- Cited by
- 173
- References
- 16
- FWCI
- 25.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel Process of Simultaneous Removal of Nitric Oxide and Sulfur Dioxide Using a Vacuum Ultraviolet (VUV)-Activated O2/H2O/H2O2 System in A Wet VUV–Spraying Reactor. https://app.cochat.ai/papers/10.1021/acs.est.6b02753
- The paper
- Liu, Y., Wang, Q., & Pan, J. (2016). Novel Process of Simultaneous Removal of Nitric Oxide and Sulfur Dioxide Using a Vacuum Ultraviolet (VUV)-Activated O2/H2O/H2O2 System in A Wet VUV–Spraying Reactor. Environmental Science & Technology. https://doi.org/10.1021/acs.est.6b02753
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.