The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Understanding Electrochemically Activated Persulfate and Its Application to Ciprofloxacin Abatement
Abstract
This study offers insight into the roles anodic and cathodic processes play in electrochemically activated persulfate (EAP) and screens EAP as a viable technique for ciprofloxacin degradation in wastewater. Sulfate radical formation at a boron-doped diamond (BDD) anode and persulfate activation at a graphite cathode were experimentally elucidated using different electrolytes and electrochemical setups. Rapid ciprofloxacin transformation occurred via pseudo-first-order mechanisms with respect to ciprofloxacin in persulfate electrolyte, reaching 84% removal in 120 min using EAP. Transformation pathways were compared to those in nitrate and sulfate electrolytes. Ciprofloxacin removal rates in the electrochemical system were 88% and 33% faster in persulfate than nitrate and sulfate electrolytes, respectively. Total organic carbon removal rates were 93% and 48% faster in persulfate than nitrate and sulfate, respectively. Use of sulfate electrolyte resulted in removal rates 6-7 times faster than those in nitrate solution. Accelerated removal in sulfate was attributed to anodic sulfate radical formation, while enhanced removal in persulfate was associated with cathodic persulfate activation and nonradical persulfate activation at the BDD anode. Quenching experiments indicated both sulfate radicals and hydroxyl radicals contributed to degradation. Comparisons between platinum and graphite cathodes showed similar cathodic persulfate activation and ciprofloxacin degradation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, T., Chen, Y., Wang, Y., Le Roux, J., Yang, Y., & Croué, J.-P. (2014) · Environmental Science & Technology · doi:10.1021/es501218f · Cited by 798
Cited by
Yan, Y., Wei, Z., Duan, X., Long, M., Spinney, R., Dionysiou, D. D., Xiao, R., & Alvarez, P. J. J. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c05153 · Cited by 726
Ganiyu, S. O., Martínez-Huitle, C. A., & Oturan, M. A. (2021) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2020.100678 · Cited by 483
Martínez-Huitle, C. A., Rodrigo, M. A., Sirés, I., & Scialdone, O. (2023) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2023.122430 · Cited by 446
Adsorption of ciprofloxacin from water: A comprehensive review
Igwegbe, C. A., Oba, S. N., Aniagor, C. O., Adeniyi, A. G., & Ighalo, J. O. (2021) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2020.09.023 · Cited by 441
Lim, J., Yang, Y., & Hoffmann, M. R. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b01449 · Cited by 404
Metadata
- Authors
- Matzek, L. W., Tipton, M. J., Farmer, A. T., Steen, A. D., & Carter, K. E.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-04-13
- Volume
- 52
- Issue
- 10
- Pages
- 5875-5883
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2798207716
- Cited by
- 199
- References
- 1
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.