Field and Laboratory Evaluations of the Low-Cost Plantower Particulate Matter Sensor
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Due to the rapid development of low-cost air-quality sensors, a rigorous scientific evaluation has not been conducted for many available sensors. We evaluated three Plantower PMS A003 sensors when exposed to eight particulate matter (PM) sources (i.e., incense, oleic acid, NaCl, talcum powder, cooking emissions, and monodispersed polystyrene latex spheres under controlled laboratory conditions and also residential air and ambient outdoor air in Baltimore, MD). The PM 2.5 sensors exhibited a high degree of precision and R 2 values greater than 0.86 for all sources, but the accuracy ranged from 13 to >90% compared with reference instruments. The sensors were most accurate for PM with diameters below 1 μm, and they poorly measured PM in the 2.5–5 μm range. The accuracy of the sensors was dependent on relative humidity (RH), with decreases in accuracy at RH > 50%. The sensors were able to produce meaningful data at low and high temperatures and when in motion, as it would be if utilized for outdoor or personal monitoring applications. It was most accurate in environments with polydispersed particle sources and may not be useful in specialized environments or experiments with narrow distributions of PM or aerosols with a large proportion of coarse PM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evolution of Organic Aerosols in the Atmosphere
Jimenez, J. L., Canagaratna, M. R., Donahue, N. M., Prevot, A. S. H., Zhang, Q., Kroll, J. H., DeCarlo, P. F., Allan, J. D., Coe, H., Ng, N. L., et al. (2009) · Science · doi:10.1126/science.1180353 · Cited by 4,167
Formation of Urban Fine Particulate Matter
Zhang, R., Wang, G., Guo, S., Zamora, M. L., Ying, Q., Lin, Y., Wang, W., Hu, M., & Wang, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00067 · Cited by 1,426
Self-citation
Cited by
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Barkjohn, K. K., Gantt, B., & Clements, A. L. (2021) · Atmospheric Measurement Techniques · doi:10.5194/amt-14-4617-2021 · Cited by 392
Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site
Feenstra, B., Papapostolou, V., Hasheminassab, S., Zhang, H., Boghossian, B. D., Cocker, D., & Polidori, A. (2019) · Atmospheric Environment · doi:10.1016/j.atmosenv.2019.116946 · Cited by 265
Assessing the accuracy of low-cost optical particle sensors using a physics-based approach
Hagan, D. H., & Kroll, J. H. (2020) · Atmospheric Measurement Techniques · doi:10.5194/amt-13-6343-2020 · Cited by 231
“Levy Zamora M, Xiong F, Gentner D, Kerkez B, Kohrman-Glaser J, and Koehler K: Field and Laboratory Evaluations of the Low-Cost Plantower Particulate Matter Sensor, Environ.”
BackgroundBi, J., Wildani, A., Chang, H. H., & Liu, Y. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.9b06046 · Cited by 227
Metadata
- Authors
- Levy Zamora, M., Xiong, F., Gentner, D., Kerkez, B., Kohrman-Glaser, J., & Koehler, K.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-18
- Volume
- 53
- Issue
- 2
- Pages
- 838-849
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2904147937
- Cited by
- 244
- References
- 2
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Field and Laboratory Evaluations of the Low-Cost Plantower Particulate Matter Sensor. https://app.cochat.ai/papers/10.1021/acs.est.8b05174
- The paper
- Levy Zamora, M., Xiong, F., Gentner, D., Kerkez, B., Kohrman-Glaser, J., & Koehler, K. (2019). Field and Laboratory Evaluations of the Low-Cost Plantower Particulate Matter Sensor. Environmental Science & Technology. https://doi.org/10.1021/acs.est.8b05174
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.