The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Faradaic Reactions in Water Desalination by Batch-Mode Capacitive Deionization
Open accessAbstract
Abstract Non-Faradaic (ion electrosorption) and Faradaic (oxidation–reduction) effects in a batch-mode capacitive deionization (CDI) system were investigated, with results showing that both effects were enhanced with an increase in charging voltage (0.5–1.5 V). Significant concentrations of hydrogen peroxide (H2O2) were observed with the generation of H2O2 initiated by cathodic reduction of O2 with subsequent consumption occurring as a result of cathodic reduction of H2O2. A kinetic model of the Faradaic processes was developed and found to satisfactorily describe the variation in the steady-state concentration of H2O2 generated over a range of CDI operating conditions. Significant pH fluctuations were observed at higher charging voltages. While the occurrence of Faradaic reactions may well contribute to pH fluctuations and deterioration of electrode stability and performance, the presence of H2O2 could provide the means of inducing disinfection or trace contaminant degradation provided H2O2 could be effectively activated to more powerful oxidants (by, for example, ultraviolet irradiation).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reverse osmosis desalination: Water sources, technology, and today's challenges
Greenlee, L. F., Lawler, D. F., Freeman, B. D., Marrot, B., & Moulin, P. (2009) · Water Research · doi:10.1016/j.watres.2009.03.010 · Cited by 3,409
Review on the science and technology of water desalination by capacitive deionization
Porada, S., Zhao, R., van der Wal, A., Presser, V., & Biesheuvel, P. M. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.03.005 · Cited by 2,152
Principles and applications of aquatic chemistry
(1993) · Choice Reviews Online · doi:10.5860/choice.31-0941 · Cited by 1,725
Water desalination via capacitive deionization: what is it and what can we expect from it?
Suss, M. E., Porada, S., Sun, X., Biesheuvel, P. M., Yoon, J., & Presser, V. (2015) · Energy & Environmental Science · doi:10.1039/c5ee00519a · Cited by 1,712
Global Kinetic Explorer: A new computer program for dynamic simulation and fitting of kinetic data
Johnson, K. A., Simpson, Z. B., & Blom, T. (2009) · Analytical Biochemistry · doi:10.1016/j.ab.2008.12.024 · Cited by 595
Zhao, R., Porada, S., Biesheuvel, P. M., & van der Wal, A. (2013) · Desalination · doi:10.1016/j.desal.2013.08.017 · Cited by 383
Wang, H., Shi, L., Yan, T., Zhang, J., Zhong, Q., & Zhang, D. (2014) · J. Mater. Chem. A · doi:10.1039/c3ta15152b · Cited by 353
Energy Recovery in Membrane Capacitive Deionization
Długołęcki, P., & van der Wal, A. (2013) · Environmental Science & Technology · doi:10.1021/es3053202 · Cited by 344
Cohen, I., Avraham, E., Bouhadana, Y., Soffer, A., & Aurbach, D. (2013) · Electrochimica Acta · doi:10.1016/j.electacta.2013.05.029 · Cited by 282
Wen, X., Zhang, D., Yan, T., Zhang, J., & Shi, L. (2013) · Journal of Materials Chemistry A · doi:10.1039/c3ta12683h · Cited by 247
Cited by
Faradaic reactions in capacitive deionization (CDI) - problems and possibilities: A review
Zhang, C., He, D., Ma, J., Tang, W., & Waite, T. D. (2018) · Water Research · doi:10.1016/j.watres.2017.10.024 · Cited by 765
Self-citationSrimuk, P., Su, X., Yoon, J., Aurbach, D., & Presser, V. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0193-1 · Cited by 665
Electrochemical Methods for Water Purification, Ion Separations, and Energy Conversion
Alkhadra, M. A., Su, X., Suss, M. E., Tian, H., Guyes, E. N., Shocron, A. N., Conforti, K. M., de Souza, J. P., Kim, N., Tedesco, M., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00396 · Cited by 661
Various cell architectures of capacitive deionization: Recent advances and future trends
Tang, W., Liang, J., He, D., Gong, J., Tang, L., Liu, Z., Wang, D., & Zeng, G. (2019) · Water Research · doi:10.1016/j.watres.2018.11.064 · Cited by 461
Self-citationTang, W., He, D., Zhang, C., Kovalsky, P., & Waite, T. D. (2017) · Water Research · doi:10.1016/j.watres.2017.05.009 · Cited by 332
Self-citation
Metadata
- Authors
- He, D., Wong, C. E., Tang, W., Kovalsky, P., & Waite, T. D.
- Venue
- Environmental Science & Technology Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-05-02
- Volume
- 3
- Issue
- 5
- Pages
- 222-226
- ISSN
- 2328-8930 (ISSN-L)
- OpenAlex
- W2343930434
- Cited by
- 330
- References
- 20
- FWCI
- 17.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Faradaic Reactions in Water Desalination by Batch-Mode Capacitive Deionization. https://app.cochat.ai/papers/10.1021/acs.estlett.6b00124
- The paper
- He, D., Wong, C. E., Tang, W., Kovalsky, P., & Waite, T. D. (2016). Faradaic Reactions in Water Desalination by Batch-Mode Capacitive Deionization. Environmental Science & Technology Letters. https://doi.org/10.1021/acs.estlett.6b00124
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.