The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Green Synthesis of Magnetic Nanocomposite with Iron Oxide Deposited on Cellulose Nanocrystals with Copper (Fe3O4@CNC/Cu): Investigation of Catalytic Activity for the Development of a Venlafaxine Electrochemical Sensor
Abstract
A screen-printed electrochemical sensor based on Fe 3 O 4 @cellulose nanocrystals/Cu nanocomposite (Fe 3 O 4 @CNC/Cu) has been constructed for the sensitive detection of venlafaxine. The magnetic Fe 3 O 4 @cellulose nanocrystal/Cu nanocomposite was prepared by a green procedure using a plant extract ( Petasites hybridus leaf) as a stabilizing and reducing agent for copper. The formation of Fe 3 O 4 @CNC/Cu was validated through X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy, field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, ultraviolet–visible spectral analysis, vibrating sample magnetometer, and thermal analysis. Fe 3 O 4 @CNC/Cu was next used for modifying a graphite screen-printed electrode, intended for the analysis of venlafaxine concentration. The electrochemical behavior of venlafaxine on the resulting electrode was evaluated through cyclic and differential pulse voltammetry and chronoamperometry. The tests indicated that the sensor has good performance for the electrochemical detection of venlafaxine. Under optimized conditions, the linear dynamic range for venlafaxine concentrations by the modified electrode was 0.05–600.0 μM, and the limit of detection was 0.01 μM. In addition, the developed technique was also demonstrated as a selective, easy, and precise sensor to identify venlafaxine in urine, water, and pharmaceutical formulation samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Cited by
Qian, L., Durairaj, S., Prins, S., & Chen, A. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112836 · Cited by 396
Zhang, Y., Zhao, G., Xuan, Y., Gan, L., & Pan, M. (2021) · Cellulose · doi:10.1007/s10570-020-03581-0 · Cited by 80
Metadata
- Authors
- Khalilzadeh, M. A., Tajik, S., Beitollahi, H., & Venditti, R. A.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-02-12
- Volume
- 59
- Issue
- 10
- Pages
- 4219-4228
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W3006468637
- Cited by
- 183
- References
- 1
- FWCI
- 11.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Green Synthesis of Magnetic Nanocomposite with Iron Oxide Deposited on Cellulose Nanocrystals with Copper (Fe3O4@CNC/Cu): Investigation of Catalytic Activity for the Development of a Venlafaxine Electrochemical Sensor. https://app.cochat.ai/papers/10.1021/acs.iecr.9b06214
- The paper
- Khalilzadeh, M. A., Tajik, S., Beitollahi, H., & Venditti, R. A. (2020). Green Synthesis of Magnetic Nanocomposite with Iron Oxide Deposited on Cellulose Nanocrystals with Copper (Fe3O4@CNC/Cu): Investigation of Catalytic Activity for the Development of a Venlafaxine Electrochemical Sensor. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/acs.iecr.9b06214
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.