Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 242

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Design of Single-Molecule Magnets: Insufficiency of the Anisotropy Barrier as the Sole Criterion

Open access
Pedersen, Kasper S., Dreiser, Jan, Weihe, Høgni, Sibille, Romain, Johannesen, Heini V., Sørensen, Mikkel A., Nielsen, Bjarne E., Sigrist, Marc, Mutka, Hannu, Rols, Stephane, Bendix, Jesper, Piligkos, Stergios·2015·Inorganic Chemistry

Abstract

Determination of the electronic energy spectrum of a trigonal-symmetry mononuclear Yb(3+) single-molecule magnet (SMM) by high-resolution absorption and luminescence spectroscopies reveals that the first excited electronic doublet is placed nearly 500 cm(-1) above the ground one. Fitting of the paramagnetic relaxation times of this SMM to a thermally activated (Orbach) model {τ = τ0 × exp[ΔOrbach/(kBT)]} affords an activation barrier, ΔOrbach, of only 38 cm(-1). This result is incompatible with the spectroscopic observations. Thus, we unambiguously demonstrate, solely on the basis of experimental data, that Orbach relaxation cannot a priori be considered as the main mechanism determining the spin dynamics of SMMs. This study highlights the fact that the general synthetic approach of optimizing SMM behavior by maximization of the anisotropy barrier, intimately linked to the ligand field, as the sole parameter to be tuned, is insufficient because of the complete neglect of the interaction of the magnetic moment of the molecule with its environment. The Orbach mechanism is expected dominant only in the cases in which the energy of the excited ligand field state is below the Debye temperature, which is typically low for molecular crystals and, thus, prevents the use of the anisotropy barrier as a design criterion for the realization of high-temperature SMMs. Therefore, consideration of additional design criteria that address the presence of alternative relaxation processes beyond the traditional double-well picture is required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.inorgchem.5b01209

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 242

Metadata

Authors
Pedersen, K. S., Dreiser, J., Weihe, H., Sibille, R., Johannesen, H. V., Sørensen, M. A., Nielsen, B. E., Sigrist, M., Mutka, H., Rols, S., Bendix, J., & Piligkos, S.
Venue
Inorganic Chemistry
Published
2015-07-22
Volume
54
Issue
15
Pages
7600-7606
ISSN
  • 0020-1669 (ISSN-L)
  • 1520-510X
OpenAlex
W1925886907
Cited by
242
References
1
FWCI
8.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design of Single-Molecule Magnets: Insufficiency of the Anisotropy Barrier as the Sole Criterion. https://app.cochat.ai/papers/10.1021/acs.inorgchem.5b01209
The paper
Pedersen, K. S., Dreiser, J., Weihe, H., Sibille, R., Johannesen, H. V., Sørensen, M. A., Nielsen, B. E., Sigrist, M., Mutka, H., Rols, S., Bendix, J., & Piligkos, S. (2015). Design of Single-Molecule Magnets: Insufficiency of the Anisotropy Barrier as the Sole Criterion. Inorganic Chemistry. https://doi.org/10.1021/acs.inorgchem.5b01209

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.