Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 349

The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.

Mechanochemical and Conventional Synthesis of Zn(II)/Cd(II) Luminescent Coordination Polymers: Dual Sensing Probe for Selective Detection of Chromate Anions and TNP in Aqueous Phase

Parmar, Bhavesh, Rachuri, Yadagiri, Bisht, Kamal Kumar, Laiya, Ridhdhi, Suresh, Eringathodi·2017·Inorganic Chemistry

Abstract

Isostructural Zn(II)/Cd(II) mixed ligand coordination polymers (CPs) {[M( IPA )( L )]} n ( CP1 and CP2 ) built from isophthalic acid (H 2 IPA ) and 3-pyridylcarboxaldehyde nicotinoylhydrazone ( L ) were prepared using versatile synthetic routes: viz., diffusion of precursor solutions, conventional reflux methods, and green mechanochemical (grinding) reactions. Both robust CPs synthesized by different routes were characterized by various analytical methods, and their thermal and chemical stability as well as the phase purity was established. Crystallographic studies revealed that CP1 and CP2 are isostructural frameworks and feature a double-lined two-dimensional network composed of Zn 2+ /Cd 2+ nodes connected through IPA and pillared by the Schiff base ligand L with a double-walled edge. The photoluminescent (PL) properties of CP1 and CP2 have been exploited as dual detection fluorosensors for hexavalent chromate anions (CrO 4 2– /Cr 2 O 7 2– ) and 2,4,6-trinitrophenol (TNP) because it was observed that the emission intensity of aqueous suspensions of CPs selectively quenches by chromate anions or TNP among large pools of different anions or nitro compounds, respectively. Competitive experiments in the presence of interfering anions/other nitro compounds also revealed no major effect in the quenching efficiency, suggesting the selective detection of hexavalent chromate anions as well as TNP by the LCPs. The limits of detection by CP1 for CrO 4 2– /Cr 2 O 7 2– and TNP are 4 ppm/4 ppm and 28 ppb, respectively, whereas the limits of detection by CP2 for the same analytes are 1 ppm/1 ppm and 14 ppb, respectively. A probable mechanism for the quenching phenomena is also discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.inorgchem.6b02810

Cites

64 of 64 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 64 references

Metadata

Authors
Parmar, B., Rachuri, Y., Bisht, K. K., Laiya, R., & Suresh, E.
Venue
Inorganic Chemistry
Published
2017-02-16
Volume
56
Issue
5
Pages
2627-2638
ISSN
  • 0020-1669 (ISSN-L)
  • 1520-510X
OpenAlex
W2588454930
Cited by
349
References
64
FWCI
16.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanochemical and Conventional Synthesis of Zn(II)/Cd(II) Luminescent Coordination Polymers: Dual Sensing Probe for Selective Detection of Chromate Anions and TNP in Aqueous Phase. https://app.cochat.ai/papers/10.1021/acs.inorgchem.6b02810
The paper
Parmar, B., Rachuri, Y., Bisht, K. K., Laiya, R., & Suresh, E. (2017). Mechanochemical and Conventional Synthesis of Zn(II)/Cd(II) Luminescent Coordination Polymers: Dual Sensing Probe for Selective Detection of Chromate Anions and TNP in Aqueous Phase. Inorganic Chemistry. https://doi.org/10.1021/acs.inorgchem.6b02810

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.