The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Mixed-Ligand LMOF Fluorosensors for Detection of Cr(VI) Oxyanions and Fe3+/Pd2+ Cations in Aqueous Media
Abstract
Zn(II)/Cd(II)-based dual ligand Luminescent Metal–Organic Frameworks (LMOFs) {[M( ATA )( L )]} n · x H 2 O ( 1 ) and ( 2 ) were synthesized by versatile synthetic routes, viz., diffusion of precursor solutions, conventional reflux, and green mechanochemical (grinding) reactions from bipyridyl-based Schiff base, ( E )- N ′-(pyridin-4-ylmethylene)isonicotinohydrazide ( L ) and amino functionalized 2-aminoterephthalic acid (H 2 ATA ) as linkers. Chemical and thermal stability, phase purity, and characterization of both LMOFs were established by various analytical methods. SXRD analysis revealed the 3D framework is composed of two-dimensional [M( ATA )] n nets doubly pillared by L through the terminal nitrogen atom. Selective and sensitive detection of chromate anions (CrO 4 2– /Cr 2 O 7 2– ) and Fe 3+ /Pd 2+ cations in the aqueous phase by fluorescent quenching of the LMOFs 1 and 2 has been established. Competitive experiments in the presence of interfering anions/cations with 1 and 2 revealed no major change in the quenching efficiency. The observed limits of detection (LOD) values by 1 for CrO 4 2– /Cr 2 O 7 2– were 0.25 μM (48 ppb)/0.43 μM (126 ppb) and for Fe 3+ /Pd 2+ were 3.76 μM (0.61 ppm)/0.20 μM (35 ppb), whereas LOD values by 2 were 0.18 μM (35 ppb)/0.19 μM (55 ppb) and 1.77 μM (0.29 ppm)/0.10 μM (18 ppb), respectively. Simple fluorescent-based test paper strips have been developed for reliable and visual detection of the mentioned analytes in practical applications. The present investigation clearly demonstrates selective detection of CrO 4 2– /Cr 2 O 7 2– and Fe 3+ /Pd 2+ in aqueous media, and the probable mechanism for the quenching phenomena based on structural aspects has also been discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andrews, N. C. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912233412607 · Cited by 2,130
Cited by
Metal ion detection using luminescent-MOFs: Principles, strategies and roadmap
Razavi, S. A. A., & Morsali, A. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213299 · Cited by 262
Metadata
- Authors
- Parmar, B., Rachuri, Y., Bisht, K. K., & Suresh, E.
- Venue
- Inorganic Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-29
- Volume
- 56
- Issue
- 18
- Pages
- 10939-10949
- ISSN
- 0020-1669 (ISSN-L)
- 1520-510X
- OpenAlex
- W2751316550
- Cited by
- 176
- References
- 1
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mixed-Ligand LMOF Fluorosensors for Detection of Cr(VI) Oxyanions and Fe3+/Pd2+ Cations in Aqueous Media. https://app.cochat.ai/papers/10.1021/acs.inorgchem.7b01130
- The paper
- Parmar, B., Rachuri, Y., Bisht, K. K., & Suresh, E. (2017). Mixed-Ligand LMOF Fluorosensors for Detection of Cr(VI) Oxyanions and Fe3+/Pd2+ Cations in Aqueous Media. Inorganic Chemistry. https://doi.org/10.1021/acs.inorgchem.7b01130
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.