Comparison of Ionic Liquids to Conventional Organic Solvents for Extraction of Aromatics from Aliphatics
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Commonly used solvents for separation of aromatics from aliphatics using liquid–liquid extraction are reviewed in terms of their physical properties and separation performance. The experimental liquid–liquid measurements for conventional solvents are contrasted with the phase behavior when using an ionic liquid as the extracting component. For comparison purposes, ternary systems of heptane + toluene + extraction solvent are used as representative mixtures, where sulfolane is the main organic extraction solvent discussed. Since ionic liquid properties are drastically changed by changing the anion, comparisons are performed for 1-ethyl-3-methylimidazolium based ionic liquids using different anions. Ionic liquids containing cyano-substituted and bis(trifluoromethylsulfonyl)imide anions provide good selectivities and distribution ratios. On the basis of the phase behavior and capacities, as well as their relatively low viscosities, they appear to be competitive alternatives to organic solvents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Perry's chemical engineers' handbook
(2008) · Choice Reviews Online · doi:10.5860/choice.45-4393 · Cited by 10,121
Ullmann's Encyclopedia of Industrial Chemistry
(2000) · Wiley eBooks · doi:10.1002/14356007 · Cited by 3,543
Liquid-Liquid Extraction Data - The Line Correlation
Othmer, D. F., & Tobias, P. E. (1942) · Industrial & Engineering Chemistry · doi:10.1021/ie50390a600 · Cited by 696
Hand, D. B. (1930) · The Journal of Physical Chemistry · doi:10.1021/j150315a009 · Cited by 564
Holbrey, J. D., Reichert, W. M., Nieuwenhuyzen, M., Sheppard, O., Hardacre, C., & Rogers, R. D. (2003) · Chemical Communications · doi:10.1039/b212726a · Cited by 394
Wytze Meindersma, G., Podt, A. (. G. )., & de Haan, A. B. (2005) · Fuel Processing Technology · doi:10.1016/j.fuproc.2005.06.002 · Cited by 367
Benvenuto, M. A. (2017) · De Gruyter eBooks · doi:10.1515/9783110494471 · Cited by 325
CO2 as a Separation Switch for Ionic Liquid/Organic Mixtures
Scurto, A. M., Aki, S. N. V. K., & Brennecke, J. F. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0268682 · Cited by 317
Self-citationHanke, C. G., Johansson, A., Harper, J. B., & Lynden-Bell, R. M. (2003) · Chemical Physics Letters · doi:10.1016/s0009-2614(03)00703-6 · Cited by 240
Cited by
Han, J., Zhang, X., Jiang, J., & Li, W. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c08565 · Cited by 254
Pérez-Rodríguez, M., Pellerano, R. G., Pezza, L., & Pezza, H. R. (2018) · Talanta · doi:10.1016/j.talanta.2018.01.058 · Cited by 191
Green solvents for sustainable separation processes
Schuur, B., Brouwer, T., Smink, D., & Sprakel, L. M. J. (2019) · Current Opinion in Green and Sustainable Chemistry · doi:10.1016/j.cogsc.2018.12.009 · Cited by 126
De Boeck, M., Damilano, G., Dehaen, W., Tytgat, J., & Cuypers, E. (2018) · Talanta · doi:10.1016/j.talanta.2018.03.001 · Cited by 29
Metadata
- Authors
- Canales, R. I., & Brennecke, J. F.
- Venue
- Journal of Chemical & Engineering Data
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-04-15
- Volume
- 61
- Issue
- 5
- Pages
- 1685-1699
- ISSN
- 0021-9568 (ISSN-L)
- 1520-5134
- OpenAlex
- W2338976343
- Cited by
- 168
- References
- 39
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.