CoChat

Thermophysical Properties of the Lennard-Jones Fluid: Database and Data Assessment

Stephan, Simon, Thol, Monika, Vrabec, Jadran, Hasse, Hans · 2019 · Journal of Chemical Information and Modeling
Cited by 176

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Literature data on the thermophysical properties of the Lennard-Jones fluid, which were sampled with molecular dynamics and Monte Carlo simulations, were reviewed and assessed. The literature data were complemented by simulation data from the present work that were taken in regions in which previously only sparse data were available. Data on homogeneous state points (for given temperature T and density ρ: pressure p, thermal expansion coefficient α, isothermal compressibility β, thermal pressure coefficient γ, internal energy u, isochoric heat capacity c v, isobaric heat capacity c p, Grüneisen parameter Γ, Joule–Thomson coefficient μ JT, speed of sound w, Helmholtz energy a, and chemical potential) were considered, as well as data on the vapor–liquid equilibrium (for given T: vapor pressure p s, saturated liquid and vapor densities ρ′ and ρ″, respectively, enthalpy of vaporization Δ h v, and as well as surface tension γ). The entire set of available data, which contains about 35 000 data points, was digitalized and included in a database, which is made available in the Supporting Information of this paper. Different consistency tests were applied to assess the accuracy and precision of the data. The data on homogeneous states were evaluated pointwise using data from their respective vicinity and equations of state. Approximately 10% of all homogeneous bulk data were discarded as outliers. The vapor–liquid equilibrium data were assessed by tests based on the compressibility factor, the Clausius–Clapeyron equation, and by an outlier test. Seven particularly reliable vapor–liquid equilibrium data sets were identified. The mutual agreement of these data sets is approximately ±1% for the vapor pressure, ±0.2% for the saturated liquid density, ±1% for the saturated vapor density, and ±0.75% for the enthalpy of vaporization—excluding the region close to the critical point.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.jcim.9b00620

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Metadata

Authors
Stephan, S., Thol, M., Vrabec, J., & Hasse, H.
Venue
Journal of Chemical Information and Modeling
Published
2019-10-14
Volume
59
Issue
10
Pages
4248-4265
ISSN
  • 1549-9596 (ISSN-L)
  • 1549-960X
OpenAlex
W2980408268
Cited by
176
References
7
FWCI
5.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thermophysical Properties of the Lennard-Jones Fluid: Database and Data Assessment. https://app.cochat.ai/papers/10.1021/acs.jcim.9b00620
The paper
Stephan, S., Thol, M., Vrabec, J., & Hasse, H. (2019). Thermophysical Properties of the Lennard-Jones Fluid: Database and Data Assessment. Journal of Chemical Information and Modeling. https://doi.org/10.1021/acs.jcim.9b00620

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.