The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Influence of the Particle Shape and Density of Self-Assembled Gold Nanoparticle Sensors on LSPR and SERS
Abstract
A low-cost methodology to prepare highly sensitive sensors is reported with different nanoparticles for LSPR and SERS measurements. The LSPR and SERS sensor was self-assembled as an array of polystyrene-capped gold nanoparticles (Au NPs), produced by drop-coating a Au NP suspension on a glass surface followed by plasma etching of the polystyrene. The procedure was applied to different sizes and shapes of Au NPs, primarily 60 nm gold nanospheres and 80 nm gold nanoraspberries, created with precise control on the packing density of the array. The LSPR sensitivity and figure of merit (FOM) for the arrays of gold nanoraspberries were found to be almost 2-fold better than for the nanospheres and had a shorter penetration depth, a consequence of their small-sized surface asperities. The average measured SERS enhancement factor (EF) for the raspberries was also higher than for spheres and control over the EF was achieved using different packing densities which allowed control of the interparticle coupling enhancing the SERS response. The localized EF (hot spot) in dense arrays of nanoraspberries was measured to be in the order of a typical EF required for single molecule SERS, as demonstrated from the general agreement of experimental measurements with simulations performed using Comsol Multiphysics. This simple LSPR and SERS sensor could potentially serve as an effective platform for the identification and quantification of various analytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface enhanced Raman scattering for multiplexed detection
Dougan, J. A., & Faulds, K. (2012) · The Analyst · doi:10.1039/c2an15979a · Cited by 117
Cited by
Localized Surface Plasmon Resonance in Semiconductor Nanocrystals
Agrawal, A., Cho, S. H., Zandi, O., Ghosh, S., Johns, R. W., & Milliron, D. J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00613 · Cited by 1,014
Nagajyothi, P. C., Prabhakar Vattikuti, S. V., Devarayapalli, K. C., Yoo, K., Shim, J., & Sreekanth, T. V. M. (2020) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2019.1705103 · Cited by 291
Surface-enhanced Raman spectroscopy for bioanalysis and diagnosis
Tahir, M. A., Dina, N. E., Cheng, H., Valev, V. K., & Zhang, L. (2021) · Nanoscale · doi:10.1039/d1nr00708d · Cited by 257
Metadata
- Authors
- Yockell-Lelièvre, H., Lussier, F., & Masson, J.-F.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-14
- Volume
- 119
- Issue
- 51
- Pages
- 28577-28585
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2328982540
- Cited by
- 175
- References
- 1
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.