Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record.

Effect of Nickel Vacancies on the Room-Temperature NO2 Sensing Properties of Mesoporous NiO Nanosheets

Zhang, Jian, Zeng, Dawen, Zhu, Qiang, Wu, Jinjin, Huang, Qingwu, Xie, Changsheng · 2016 · The Journal of Physical Chemistry C

Abstract

To improve the gas-sensing performance of metal-oxide-semiconductors, the effect of defects on gas-sensing properties has been widely investigated. Nevertheless, although the metal cation defect is the dominative acceptor defect in p-type semiconductors, its effect on the gas-sensing properties remains blank, which leads to a hindrance for further developing p-type semiconductor-based gas sensors. Accordingly, to eleborate the effect of metal cation defects on the sensing properties, mesoporous NiO nanosheets with different amounts of nickel vacancies were prepared by annealing at different temperatures. It was found that the amount of nickel vacancies increased with increasing the annealing temperature. Gas-sensing studies revealed that the NiO with a higher concentration of nickel vacancies exhibited higher sensitivity to NO 2 at room temperature. With further increasing the annealing temperature to 600 °C, although the rapid decrease in the specific surface area of the NiO might limit the physisorption of NO 2, the NiO could also present a better sensitivity to NO 2 due to the abundant nickel vacancies with high activity. Furthermore, an in situ DRIFTS study demonstrated that the number of adsorbed nitrate and nitrite species on NiO surfaces increased with increasing the amount of nickel vacancies, indicating that the nickel vacancies acted as the dominative active sites participating in the gas–solid reaction and then determined the room-temperature sensing properties. According to the defect ionization equation, a hole conduction model was further proposed to decipher the dependency of sensing properties on the metal cation defects. We hope this work could make us better understand the roles of cation defect in the sensing properties, and it could also benefit the improvement of p-type semiconductor-based gas sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.jpcc.5b12162

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 167

Metadata

Authors
Zhang, J., Zeng, D., Zhu, Q., Wu, J., Huang, Q., & Xie, C.
Venue
The Journal of Physical Chemistry C
Published
2016-02-17
Volume
120
Issue
7
Pages
3936-3945
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2282896142
Cited by
167
References
0
FWCI
6.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Nickel Vacancies on the Room-Temperature NO2 Sensing Properties of Mesoporous NiO Nanosheets. https://app.cochat.ai/papers/10.1021/acs.jpcc.5b12162
The paper
Zhang, J., Zeng, D., Zhu, Q., Wu, J., Huang, Q., & Xie, C. (2016). Effect of Nickel Vacancies on the Room-Temperature NO2 Sensing Properties of Mesoporous NiO Nanosheets. The Journal of Physical Chemistry C. https://doi.org/10.1021/acs.jpcc.5b12162

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.