Cited by 27Electrostatics and Colloid InteractionsIonic liquids properties and applicationsNanopore and Nanochannel Transport Studies

Confinement Induced Dilution: Electrostatic Screening Length Anomaly in Concentrated Electrolytes in Confined Space

Huang, Jun·2018·The Journal of Physical Chemistry C

Abstract

For electrolytes confined in nanoscale space, a growing body of experimental evidence suggests that the electrostatic screening length (or Debye length) increases with the electrolyte concentration in the concentrated regime (e.g., ionic liquids). This electrostatic screening length anomaly can be understood under the assumption of an effectively dilute electrolyte due to massive ion-pairing, which, however, contradicts with the conventional wisdom that ionic liquids are highly dissociated, given the negative free energy of dissociation. To resolve this puzzle, a phenomenological theory is developed to understand ion-pair dissociation in electrolytes in confined space . Nanoconfinement suppresses lattice expansion upon ion-pair dissociation, shifting the effective free energy of dissociation toward positive values, favoring massive ion-pairing, and rendering a long electrostatic screening length. The dependence of the electrostatic screening length on the temperature and the ionic size is discussed. It is of high priority to investigate the nanoconfinement effect of the differential double-layer capacitance C dl to further corroborate the confinement induced dilution phenomenon.

Integrity signals

Registry

Crossref · 10.1021/acs.jpcc.7b11093

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A theoretical calculation considering the SFA mechanism has shown that spatial confinement makes the formation of massive ion pairs favorable even in a simple NaCl solution at high concentration.

    “The theoretical calculation specifically considering the SFA mechanism has shown that the spatial confinement makes the formation of massive ion pairs become favorable even in a simple NaCl solution in highly concentrated condition [19].”
  • Above a certain solute concentration (0.4 M reported in Ref. [19]), the content of total ions in NaCl solution participating in the screening of surface charge decreases dramatically, and the decay length is expected to increase.

    “As the solute concentration increases above a certain value (which is 0.4 M reported in Ref. [19]), the content of total ions in NaCl solution that participate in the screening of surface charge will experience a dramatic decrease, when the decay length is expected to increase.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Huang, J.
Affiliations
Central South University (CN)
Corresponding author
Huang, Jun
Venue
The Journal of Physical Chemistry C
Published
2018-02-05
Volume
122
Issue
6
Pages
3428-3433
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2790237328
Cited by
27
References
1
Citations by year
2026: 1 · 2025: 3 · 2024: 2 · 2023: 3 · 2021: 3 · 2020: 6 · 2019: 7 · 2018: 2
FWCI
3.17
Type
journal article
Language
en
Open access
closed
Locations
The Journal of Physical Chemistry C (publishedVersion)
Funders
Starting fund for new faculty members at Central South University (502045001)
Topics
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Electrostatics and Colloid Interactions
  • Physical Sciences › Chemical Engineering › Catalysis › Ionic liquids properties and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Nanopore and Nanochannel Transport Studies
Keywords
Debye length, concentrated electrolytes, nanoconfinement, ionic liquids, ion pairing, ion pair dissociation, lattice expansion, dissociation free energy, double-layer capacitance, temperature dependence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review