We report the development of a completely automated pipeline to monitor system suitability in bottom-up proteomic experiments. LC-MS/MS runs are automatically imported into Skyline and multiple identification-free metrics are extracted from targeted peptides. These data are then uploaded to the Panorama Skyline document repository where metrics can be viewed in a web-based interface using powerful process control techniques, including Levey-Jennings and Pareto plots. The interface is versatile and takes user input, which allows the user significant control over the visualization of the data. The pipeline is vendor and instrument-type neutral, supports multiple acquisition techniques (e.g., MS 1 filtering, data-independent acquisition, parallel reaction monitoring, and selected reaction monitoring), can track performance of multiple instruments, and requires no manual intervention aside from initial setup. Data can be viewed from any computer with Internet access and a web browser, facilitating sharing of QC data between researchers. Herein, we describe the use of this pipeline, termed Panorama AutoQC, to evaluate LC-MS/MS performance in a range of scenarios including identification of suboptimal instrument performance, evaluation of ultrahigh pressure chromatography, and identification of the major sources of variation throughout years of peptide data collection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.jproteome.6b00744

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 68

Metadata

Authors
Bereman, M. S., Beri, J., Sharma, V., Nathe, C., Eckels, J., MacLean, B., & MacCoss, M. J.
Venue
Journal of Proteome Research
Published
2016-10-04
Volume
15
Issue
12
Pages
4763-4769
ISSN
  • 1535-3893 (ISSN-L)
  • 1535-3907
OpenAlex
W2524383220
Cited by
68
References
2
FWCI
3.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Automated Pipeline to Monitor System Performance in Liquid Chromatography–Tandem Mass Spectrometry Proteomic Experiments. https://app.cochat.ai/papers/10.1021/acs.jproteome.6b00744
The paper
Bereman, M. S., Beri, J., Sharma, V., Nathe, C., Eckels, J., MacLean, B., & MacCoss, M. J. (2016). An Automated Pipeline to Monitor System Performance in Liquid Chromatography–Tandem Mass Spectrometry Proteomic Experiments. Journal of Proteome Research. https://doi.org/10.1021/acs.jproteome.6b00744

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.