Cited by 40Advanced biosensing and bioanalysis techniquesMolecular Sensors and Ion DetectionMagnetic Properties and Synthesis of Ferrites

The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.

Spinel Cobalt Ferrite Nanoparticles for Sensing Phosphate Ions in Aqueous Media and Biological Samples

Abstract

Phosphate ions perform a variety of functions in metabolic processes and are essential for all living organisms. The determination of the concentration of phosphate ions is useful in clinical diagnosis of various diseases as an inadequate phosphate level could lead to many health problems. In the search for a cost-effective method of fast monitoring, we investigated the use of cobalt ferrite nanoparticles (CoFeNPs) in the selective recognition of phosphate ions dissolved in aqueous media and more complex samples, such as human blood serum. We prepared these NPs by a chemical coprecipitation route and subjected them to annealing at 600 °C for 1 h. The successful formation of the NPs was confirmed by Fourier transform infrared spectroscopy, X-ray diffraction, transmission electron microscopy, and hysteresis loop measurements. The NPs exhibited a ferrimagnetic behavior, a spinel-type crystalline structure, and hexagonal shape in the nanoscale range. We demonstrated that CoFeNPs containing immobilized fluorescent-labeled single-chain DNA (ssDNA*) probes can be applied for the fast selective detection of phosphate ions dissolved in a liquid medium. We have explored the fact that phosphate groups can displace ssDNA* probes attached to the nanoparticles, therefore causing a perceptible change in the fluorescence signal of the supernatant liquid. This detection method has been tested for the sensing of phosphate ions present both in aqueous solutions and in biological samples, with excellent selectivity and a low limit of detection (∼1.75 nM).

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.langmuir.9b02901

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 60 references

Research works printed but not linked: 3

  1. Adams, J. G. Emergency Medicine; Elsevier Health Sciences, 2018; p 1416.
  2. Shahjuee T., 2017, J. Ultrafine Grained Nanostruct. Mater., 50, 105
  3. Wan Azelee I., 2014, Indian J. Mar. Sci., 43, 372

Cited by

Metadata

Authors
Ratkovski, G. P., do Nascimento, K. T. O., Pedro, G. C., Ratkovski, D. R., Gorza, F. D. S., da Silva, R. J., Maciel, B. G., Mojica-Sánchez, L. C., & de Melo, C. P.
Affiliations
Universidade Federal de Pernambuco (BR)
Corresponding author
de Melo, Celso P.
Venue
Langmuir
Published
2020-03-02
Volume
36
Issue
11
Pages
2920-2929
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W3009475981
Cited by
40
References
60
Citations by year
2026: 5 · 2025: 7 · 2024: 9 · 2022: 6 · 2021: 11 · 2020: 2
FWCI
1.54
Type
journal article
Language
en
Open access
closed
Locations
  • Langmuir (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Funda??o de Amparo ? Ci?ncia e Tecnologia do Estado de Pernambuco
  • Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico
  • Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior
  • Funda??o Nacional de Sa?de
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
  • Physical Sciences › Materials Science › Materials Chemistry › Magnetic Properties and Synthesis of Ferrites
Keywords
cobalt ferrite nanoparticles, phosphate ion detection, fluorescent DNA probes, spinel ferrite, chemical coprecipitation, annealing, fluorescence sensing, human serum, aqueous media, ferrimagnetic nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review