Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Elastic Long-Chain Multication Cross-Linked Anion Exchange Membranes

Han, Juanjuan, Zhu, Liang, Pan, Jing, Zimudzi, Tawanda J., Wang, Ying, Peng, Yanqiu, Hickner, Michael A., Zhuang, Lin·2017·Macromolecules

Abstract

Anion exchange membranes (AEMs) are a promising class of materials that enable non-noble metals to be used as catalysts in fuel cells. Compared to their acidic counterparts, typically Nafion and other perfluorosulfonate-based membranes, the low OH – conductivity in AEMs remains a concern as these materials are developed for practical applications. Cross-linked macromolecular structures are a popular way to optimize the trade-off between the ionic conductivity and the water swelling of AEMs with high ion exchange capacities (IECs). However, common cross-linked AEMs (e.g., x (QH)QPPO) that have high degrees of cross-linking with low molecular weight between cross-links are usually mechanically brittle. Moreover, the cross-links in AEMs can hinder the transport of OH –, leading to unsatisfactory conductivities. Here we report a series of elastic and highly conductive poly(2,6-dimethylphenylene oxide) (PPO)-based AEMs ( x (QH) 3 QPPO) containing flexible, long-chain, multication cross-links. The strength and flexibility of the x (QH) 3 QPPO samples are significantly improved as compared to the conventional x (QH)QPPO membranes and multication un-cross-linked materials reported previously. The high conductivities in these new materials ( x (QH) 3 QPPO-40, IEC = 3.59 mmol/g, σ OH – = 110.2 mS/cm at 80 °C) are attributed to the distinct microphase separation observed in the x (QH) 3 QPPO membranes by SAXS and TEM analyses. Furthermore, the x (QH) 3 QPPO samples exhibit good dimensional (swelling ratio of x (QH) 3 QPPO-40 is 25.0% at 80 °C) and chemical (22% and 25% decrease in IEC and OH – conductivity in 1 M NaOH at 80 °C for 30 days, respectively) stabilities, making this cross-linking motif suitable for potential membrane applications in fuel cells and other electrochemical devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.macromol.6b01140

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 212

Metadata

Authors
Han, J., Zhu, L., Pan, J., Zimudzi, T. J., Wang, Y., Peng, Y., Hickner, M. A., & Zhuang, L.
Venue
Macromolecules
Published
2017-04-03
Volume
50
Issue
8
Pages
3323-3332
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W2604774874
Cited by
212
References
3
FWCI
9.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.