Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 219

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Wavelength-Dependent Photochemistry of Oxime Ester Photoinitiators

Fast, David E., Lauer, Andrea, Menzel, Jan P., Kelterer, Anne-Marie, Gescheidt, Georg, Barner-Kowollik, Christopher · 2017 · Macromolecules

Abstract

The design of efficient radical photoinitiating systems requires a systematic and detailed evaluation of their photochemical characteristics. Correlating absorbance and the corresponding electronic transitions of a photoinitiator is critical for understanding its photoinduced reaction pathways. In the current contribution, we provide an in-depth investigation into the photochemistry and photophysics of two oxime ester derivatives ( O -benzoyl-α-oxooxime, OXE01, and O -acetyloxime, OXE02 ), known for their excellent performance in pigmented formulations. In particular, we shed light on their wavelength-dependent photopolymerization properties. We utilized a combination of UV–vis spectroscopy, density functional theory (DFT) calculations, photochemically induced dynamic nuclear polarization spectroscopy (photo-CIDNP), and pulsed-laser polymerization with a wavelength-tunable laser with subsequent size exclusion chromatography coupled to high-resolution electrospray ionization mass spectrometry (PLP-SEC-ESI-MS) for obtaining detailed insights. Both photoinitiators have high molar extinction coefficients (ε) of greater than 1.75 × 10 4 L mol –1 cm –1 at close to 330 nm, with the n−π* and π–π* transitions, relevant for cleavage of the N–O bond, at approximately 335 nm according to DFT calculations. We have probed the wavelength-dependent initiation behavior of both OXE01 and OXE02 in the presence of methyl methacrylate (MMA) via PLP with a wavelength-tunable laser between 285 and 435 nm at constant photon counts. Surprisingly, the highest conversions of MMA were found at a wavelength of 405 nm, even though the molar extinction coefficients of the photoinitiators are low (ε 405 of 45 and 2 L mol –1 cm –1 for OXE01 and OXE02, respectively) compared with shorter wavelengths. Accordingly, the absorption spectrum of a photoinitiator is not a straightforward guide for selecting the most efficient excitation wavelength.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.macromol.7b00089

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 219

Metadata

Authors
Fast, D. E., Lauer, A., Menzel, J. P., Kelterer, A.-M., Gescheidt, G., & Barner-Kowollik, C.
Venue
Macromolecules
Published
2017-03-02
Volume
50
Issue
5
Pages
1815-1823
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W2592634495
Cited by
219
References
3
FWCI
7.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wavelength-Dependent Photochemistry of Oxime Ester Photoinitiators. https://app.cochat.ai/papers/10.1021/acs.macromol.7b00089
The paper
Fast, D. E., Lauer, A., Menzel, J. P., Kelterer, A.-M., Gescheidt, G., & Barner-Kowollik, C. (2017). Wavelength-Dependent Photochemistry of Oxime Ester Photoinitiators. Macromolecules. https://doi.org/10.1021/acs.macromol.7b00089

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.