Cited by 18Polymer crystallization and propertiesSpectroscopy and Chemometric AnalysesSpectroscopy Techniques in Biomedical and Chemical Research

Relating Post-yield Mechanical Behavior in Polyethylenes to Spatially Varying Molecular Deformation Using Infrared Spectroscopic Imaging: Homopolymers

Mukherjee, Prabuddha, Ghosh, Ayanjeet, Spegazzini, Nicolas, Lamborn, Mark J., Monwar, Masud M., DesLauriers, Paul J., Bhargava, Rohit·2018·Macromolecules

Abstract

Stress–strain curves derived from tensile specimens are the primary characteristic of bulk polymers’ mechanical properties. Current tools, however, cannot provide molecular insights from this single bulk measurement. Hence, we use Fourier transform infrared (FT-IR) spectroscopic imaging to optically and nondestructively measure molecular structure and its spatial dependence in tensile specimens in high density polyethylene homopolymers. To overcome the limitations of FT-IR imaging, we use an emerging approach involving the use of tunable quantum cascade lasers that allows imaging through thick samples and facile polarized light imaging. Crystal structure and orientation are obtained from spatially varying measurements of molecular properties in the necking region. Local molecular (re)arrangements to characterize mechanical properties of drawn samples are deduced from spectral data. A modified Eyring model was developed to quantitatively understand spatial dependence in terms of a conformational volume. We report the strain rise in high density polyethylene homopolymers is governed by the degree of association between the crystalline domains. Together, the new measurement technology and analysis reported here can relate molecular composition, microscopic gradients, and orientation to bulk mechanical properties of semicrystalline polymers.

Integrity signals

Registry

Crossref · 10.1021/acs.macromol.8b00363

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Authors
Mukherjee, P., Ghosh, A., Spegazzini, N., Lamborn, M. J., Monwar, M. M., DesLauriers, P. J., & Bhargava, R.
Affiliations
  • University of Illinois Urbana-Champaign (US)
  • Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana−Champaign, Urbana, Illinois 61801, United States
  • Chevron Phillips Chemical (United States) (US)
Corresponding author
  • DesLauriers, Paul J.
  • Bhargava, Rohit
Venue
Macromolecules
Published
2018-05-10
Volume
51
Issue
10
Pages
3836-3844
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W2799810360
Cited by
18
References
0
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2022: 7 · 2021: 1 · 2020: 3 · 2019: 2 · 2018: 1
FWCI
0.87
Type
journal article
Language
en
Open access
closed
Locations
Macromolecules (publishedVersion)
Funders
  • Agilent Technologies (Thought Leader Award)
  • Chevron Phillips Chemical Company LP
Topics
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
high-density polyethylene, molecular deformation, quantum cascade lasers, polarization imaging, molecular reorganization, Eyring model, semicrystalline polymers, tensile deformation, molecular orientation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review