CoChat

Optical Monitoring of In Situ Iron Loading into Single, Native Ferritin Proteins

Open access

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Abstract

Ferritin is a protein that stores and releases iron to prevent diseases associated with iron dysregulation in plants, animals, and bacteria. The conversion between iron-loaded holo-ferritin and empty apo-ferritin is an important process for iron regulation. To date, studies of ferritin have used either ensemble measurements to quantify the characteristics of a large number of proteins or single-molecule approaches to interrogate labeled or modified proteins. Here we demonstrate the first real-time study of the dynamics of iron ion loading and biomineralization within a single, unlabeled ferritin protein. Using optical nanotweezers, we trapped single apo- and holo-ferritins indefinitely, distinguished one from the other, and monitored their structural dynamics in real time. The study presented here deepens the understanding of the iron uptake mechanism of ferritin proteins, which may lead to new therapeutics for iron-related diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.nanolett.3c00042

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Schematic of optical nanotweezer setup. A syringe pump withdraws different buffers through a 12-way valve and then injects the buffer into the flowcell with controllable flow rates. The fused silica chip containing a double-nanohole (DNH) in a thin gold film is mounted in the flowcell. A collimated laser beam with a wavelength of 852 nm is focused on the DNH by a 60× air objective with NA 0.85. The transmitted light is collected by a 10× objective and then detected by an avalanche photodiode (APD). Right inset: scanning electron microscopy (SEM) image of a DNH structure in a 100 nm gold film, taken at an angle of 20° above the plane.
Figure 1 Schematic of optical nanotweezer setup. A syringe pump withdraws different buffers through a 12-way valve and then injects the buffer into the flowcell with controllable flow rates. The fused silica chip containing a double-nanohole (DNH) in a thin gold film is mounted in the flowcell. A collimated laser beam with a wavelength of 852 nm is focused on the DNH by a 60× air objective with NA 0.85. The transmitted light is collected by a 10× objective and then detected by an avalanche photodiode (APD). Right inset: scanning electron microscopy (SEM) image of a DNH structure in a 100 nm gold film, taken at an angle of 20° above the plane.CC BY · PubMed Central
Figure 2 Optical signals from the DNH reveal the difference in structural dynamics between apo- and holo-ferritin at a single-molecule level. (a, b) Transmission signal through the same DNH upon trapping a single apo-ferritin (a, blue) and holo-ferritin (b, red) for 12 s. Insets: crystal structure of apo-ferritin (PDB: 2W0O) and holo-ferritin (PDB: 6TRZ) with curved lines indicating their structural fluctuation in the trap. (c) (left) 1 s magnified trace from (a) and (b) normalized to the transmission value with the highest probability of each trace. (right) Box plot indicating the interquartile range along with the violin plot of two 1 s traces filtered at 1 kHz. (d) Probability density function (PDF) of the transmitted optical signal calculated from 12 s traces of trapping an apo-ferritin ((a) blue) and a holo-ferritin ((b) red). All of the traces were digitally filtered with a cutoff frequency of 1 kHz. Data were acquired at 1 MHz.
Figure 2 Optical signals from the DNH reveal the difference in structural dynamics between apo- and holo-ferritin at a single-molecule level. (a, b) Transmission signal through the same DNH upon trapping a single apo-ferritin (a, blue) and holo-ferritin (b, red) for 12 s. Insets: crystal structure of apo-ferritin (PDB: 2W0O) and holo-ferritin (PDB: 6TRZ) with curved lines indicating their structural fluctuation in the trap. (c) (left) 1 s magnified trace from (a) and (b) normalized to the transmission value with the highest probability of each trace. (right) Box plot indicating the interquartile range along with the violin plot of two 1 s traces filtered at 1 kHz. (d) Probability density function (PDF) of the transmitted optical signal calculated from 12 s traces of trapping an apo-ferritin ((a) blue) and a holo-ferritin ((b) red). All of the traces were digitally filtered with a cutoff frequency of 1 kHz. Data were acquired at 1 MHz.CC BY · PubMed Central
Figure 3 Comparison of the optical trapping signal of individual apo-ferritins and holo-ferritins. (a) Normalized root-mean-square (NRMS) of transmission signal when an apo-ferritin (blue) and a holo-ferritin (red) are trapped in six different DNH structures. (b) PDF of 20 s traces with apo-ferritin (blue) and holo-ferritin (red) trapped in six different DNH structures. Data were acquired at 1 MHz and then Gaussian filtered at 1 kHz. Asterisks indicate statistically significant differences (****p < 0.0001).
Figure 3 Comparison of the optical trapping signal of individual apo-ferritins and holo-ferritins. (a) Normalized root-mean-square (NRMS) of transmission signal when an apo-ferritin (blue) and a holo-ferritin (red) are trapped in six different DNH structures. (b) PDF of 20 s traces with apo-ferritin (blue) and holo-ferritin (red) trapped in six different DNH structures. Data were acquired at 1 MHz and then Gaussian filtered at 1 kHz. Asterisks indicate statistically significant differences (****p < 0.0001).CC BY · PubMed Central
Figure 4 In situ iron loading into a trapped apo-ferritin. (a) Continuous transmission trace of a single apo-ferritin trapped in the hot spot of a DNH and then exposed to the ferrous solution for more than 20 min. After turning off the laser for 5 s, the transmission signal returned to the baseline, indicating that protein was released. (b) 20 s transmission trace of trapped apo-ferritin before the ferrous solution reaches the hot spot, along with the PDF of the trace on the right (blue). The red dashed curve represents the PDF of (e) for comparison. (c, d) 20 s transmission traces after apo-ferritin was exposed to the ferrous solution. The segments with lower RMS are colored in purple, which is identified by RMS changes as discussed in section SI-8 in the Supporting Information. The PDF plot on the right shows the PDF of the purple segments and blue segments, respectively, as well as the PDF of the whole trace (cyan dashed curve). (e) 20 s transmission trace after apo-ferritin was exposed to the ferrous solution for more than 20 min, along with the PDF of the trace (red) and the PDF of (b) (dashed blue).
Figure 4 In situ iron loading into a trapped apo-ferritin. (a) Continuous transmission trace of a single apo-ferritin trapped in the hot spot of a DNH and then exposed to the ferrous solution for more than 20 min. After turning off the laser for 5 s, the transmission signal returned to the baseline, indicating that protein was released. (b) 20 s transmission trace of trapped apo-ferritin before the ferrous solution reaches the hot spot, along with the PDF of the trace on the right (blue). The red dashed curve represents the PDF of (e) for comparison. (c, d) 20 s transmission traces after apo-ferritin was exposed to the ferrous solution. The segments with lower RMS are colored in purple, which is identified by RMS changes as discussed in section SI-8 in the Supporting Information. The PDF plot on the right shows the PDF of the purple segments and blue segments, respectively, as well as the PDF of the whole trace (cyan dashed curve). (e) 20 s transmission trace after apo-ferritin was exposed to the ferrous solution for more than 20 min, along with the PDF of the trace (red) and the PDF of (b) (dashed blue).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Cited by

See all 37

Metadata

Authors
Yousefi, A., Ying, C., Parmenter, C. D. J., Assadipapari, M., Sanderson, G., Zheng, Z., Xu, L., Zargarbashi, S., Hickman, G. J., Cousins, R. B., Mellor, C. J., Mayer, M., & Rahmani, M.
Affiliations
  • Nottingham Trent University (GB)
  • University of Nottingham (GB)
  • University of Fribourg (CH)
Corresponding author
  • Ying, Cuifeng
  • Rahmani, Mohsen
Venue
Nano Letters
Published
2023-04-13
Volume
23
Issue
8
Pages
3251-3258
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W4365443241
Cited by
37
References
54
Citations by year
2026: 7 · 2025: 10 · 2024: 10 · 2023: 10
FWCI
7.64
Type
journal article
Language
en
Open access
Locations
  • Nano Letters (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Repository@Nottingham (University of Nottingham) (publishedVersion, other-oa)
  • Nottingham Trent University's Institutional Repository (Nottingham Trent Repository) (submittedVersion, cc-by)
Funders
  • Royal Society
  • Schweizerischer Nationalfonds zur F?rderung der Wissenschaftlichen Forschung (200020_197239)
  • Wolfson Foundation
Topics
  • Health Sciences › Medicine › Hematology › Iron Metabolism and Disorders
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
Keywords
ferritin, iron loading, apoferritin, iron biomineralization, iron regulation, protein structural dynamics, iron storage
MeSH terms
Animals, Biological Transport, Ferritins, Iron

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optical Monitoring of In Situ Iron Loading into Single, Native Ferritin Proteins. https://app.cochat.ai/papers/10.1021/acs.nanolett.3c00042
The paper
Yousefi, A., Ying, C., Parmenter, C. D. J., Assadipapari, M., Sanderson, G., Zheng, Z., Xu, L., Zargarbashi, S., Hickman, G. J., Cousins, R. B., Mellor, C. J., Mayer, M., & Rahmani, M. (2023). Optical Monitoring of In Situ Iron Loading into Single, Native Ferritin Proteins. Nano Letters. https://doi.org/10.1021/acs.nanolett.3c00042

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.