The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Infrared Photodetection Based on Colloidal Quantum-Dot Films with High Mobility and Optical Absorption up to THz
Open accessAbstract
Infrared thermal imaging devices rely on narrow band gap semiconductors grown by physical methods such as molecular beam epitaxy and chemical vapor deposition. These technologies are expensive, and infrared detectors remain limited to defense and scientific applications. Colloidal quantum dots (QDs) offer a low cost alternative to infrared detector by combining inexpensive synthesis and an ease of processing, but their performances are so far limited, in terms of both wavelength and sensitivity. Herein we propose a new generation of colloidal QD-based photodetectors, which demonstrate detectivity improved by 2 orders of magnitude, and optical absorption that can be continuously tuned between 3 and 20 μm. These photodetectors are based on the novel synthesis of n-doped HgSe colloidal QDs whose size can be tuned continuously between 5 and 40 nm, and on their assembly into solid nanocrystal films with mobilities that can reach up to 100 cm(2) V(-1) s(-1). These devices can be operated at room temperature with the same level of performance as the previous generation of devices when operated at liquid nitrogen temperature. HgSe QDs can be synthesized in large scale (>10 g per batch), and we show that HgSe films can be processed to form a large scale array of pixels. Taken together, these results pave the way for the development of the next generation mid- and far-infrared low-cost detectors and camera.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photodetectors based on graphene, other two-dimensional materials and hybrid systems
Koppens, F. H. L., Mueller, T., Avouris, P., Ferrari, A. C., Vitiello, M. S., & Polini, M. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.215 · Cited by 3,828
Mid-infrared HgTe colloidal quantum dot photodetectors
Keuleyan, S., Lhuillier, E., Brajuskovic, V., & Guyot-Sionnest, P. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.142 · Cited by 503
Self-citation
Cited by
Recent Progress and Future Prospects of 2D‐Based Photodetectors
Huo, N., & Konstantatos, G. (2018) · Advanced Materials · doi:10.1002/adma.201801164 · Cited by 730
Endeavor of Iontronics: From Fundamentals to Applications of Ion‐Controlled Electronics
Bisri, S. Z., Shimizu, S., Nakano, M., & Iwasa, Y. (2017) · Advanced Materials · doi:10.1002/adma.201607054 · Cited by 558
Two-Dimensional Colloidal Nanocrystals
Nasilowski, M., Mahler, B., Lhuillier, E., Ithurria, S., & Dubertret, B. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00164 · Cited by 525
Self-citationColloidal quantum dot electronics
Liu, M., Yazdani, N., Yarema, M., Jansen, M., Wood, V., & Sargent, E. H. (2021) · Nature Electronics · doi:10.1038/s41928-021-00632-7 · Cited by 448
MoS2–HgTe Quantum Dot Hybrid Photodetectors beyond 2 µm
Huo, N., Gupta, S., & Konstantatos, G. (2017) · Advanced Materials · doi:10.1002/adma.201606576 · Cited by 334
Metadata
- Authors
- Lhuillier, E., Scarafagio, M., Hease, P., Nadal, B., Aubin, H., Xu, X. Z., Lequeux, N., Patriarche, G., Ithurria, S., & Dubertret, B.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-01-21
- Volume
- 16
- Issue
- 2
- Pages
- 1282-1286
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2236366199
- Cited by
- 205
- References
- 2
- FWCI
- 13.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.