The DOI matches its Crossref record.
Low-Frequency Interlayer Raman Modes to Probe Interface of Twisted Bilayer MoS2
Open accessAbstract
van der Waals homo- and heterostructures assembled by stamping monolayers together present optoelectronic properties suitable for diverse applications. Understanding the details of the interlayer stacking and resulting coupling is crucial for tuning these properties. We investigated the low-frequency interlayer shear and breathing Raman modes (<50 cm(-1)) in twisted bilayer MoS2 by Raman spectroscopy and first-principles modeling. Twisting significantly alters the interlayer stacking and coupling, leading to notable frequency and intensity changes of low-frequency modes. The frequency variation can be up to 8 cm(-1) and the intensity can vary by a factor of ∼5 for twisting angles near 0° and 60°, where the stacking is a mixture of high-symmetry stacking patterns and is thus sensitive to twisting. For twisting angles between 20° and 40°, the interlayer coupling is nearly constant because the stacking results in mismatched lattices over the entire sample. It follows that the Raman signature is relatively uniform. Note that for some samples, multiple breathing mode peaks appear, indicating nonuniform coupling across the interface. In contrast to the low-frequency interlayer modes, high-frequency intralayer Raman modes are much less sensitive to interlayer stacking and coupling. This research demonstrates the effectiveness of low-frequency Raman modes for probing the interfacial coupling and environment of twisted bilayer MoS2 and potentially other two-dimensional materials and heterostructures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Raman spectroscopy of graphene-based materials and its applications in related devices
Wu, J.-B., Lin, M.-L., Cong, X., Liu, H.-N., & Tan, P.-H. (2018) · Chemical Society Reviews · doi:10.1039/c6cs00915h · Cited by 2,092
Pham, P. V., Bodepudi, S. C., Shehzad, K., Liu, Y., Xu, Y., Yu, B., & Duan, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00735 · Cited by 708
Naik, M. H., & Jain, M. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.266401 · Cited by 473
Extremely anisotropic van der Waals thermal conductors
Kim, S. E., Mujid, F., Rai, A., Eriksson, F., Suh, J., Poddar, P., Ray, A., Park, C., Fransson, E., Zhong, Y., et al. (2021) · Nature · doi:10.1038/s41586-021-03867-8 · Cited by 335
Low-Frequency Shear and Layer-Breathing Modes in Raman Scattering of Two-Dimensional Materials
Liang, L., Zhang, J., Sumpter, B. G., Tan, Q.-H., Tan, P.-H., & Meunier, V. (2017) · ACS Nano · doi:10.1021/acsnano.7b06551 · Cited by 291
Self-citation
Metadata
- Authors
- Huang, S., Liang, L., Ling, X., Puretzky, A. A., Geohegan, D. B., Sumpter, B. G., Kong, J., Meunier, V., & Dresselhaus, M. S.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-01-26
- Volume
- 16
- Issue
- 2
- Pages
- 1435-1444
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2268433210
- Cited by
- 229
- References
- 0
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-Frequency Interlayer Raman Modes to Probe Interface of Twisted Bilayer MoS2. https://app.cochat.ai/papers/10.1021/acs.nanolett.5b05015
- The paper
- Huang, S., Liang, L., Ling, X., Puretzky, A. A., Geohegan, D. B., Sumpter, B. G., Kong, J., Meunier, V., & Dresselhaus, M. S. (2016). Low-Frequency Interlayer Raman Modes to Probe Interface of Twisted Bilayer MoS2. Nano Letters. https://doi.org/10.1021/acs.nanolett.5b05015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.