The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fast and Sensitive Terahertz Detection Using an Antenna-Integrated Graphene pn Junction
Open accessAbstract
Although the detection of light at terahertz (THz) frequencies is important for a large range of applications, current detectors typically have several disadvantages in terms of sensitivity, speed, operating temperature, and spectral range. Here, we use graphene as a photoactive material to overcome all of these limitations in one device. We introduce a novel detector for terahertz radiation that exploits the photothermoelectric (PTE) effect, based on a design that employs a dual-gated, dipolar antenna with a gap of ∼100 nm. This narrow-gap antenna simultaneously creates a pn junction in a graphene channel located above the antenna and strongly concentrates the incoming radiation at this pn junction, where the photoresponse is created. We demonstrate that this novel detector has an excellent sensitivity, with a noise-equivalent power of 80 pW/[Formula: see text] at room temperature, a response time below 30 ns (setup-limited), a high dynamic range (linear power dependence over more than 3 orders of magnitude) and broadband operation (measured range 1.8-4.2 THz, antenna-limited), which fulfills a combination that is currently missing in the state-of-the-art detectors. Importantly, on the basis of the agreement we obtained between experiment, analytical model, and numerical simulations, we have reached a solid understanding of how the PTE effect gives rise to a THz-induced photoresponse, which is very valuable for further detector optimization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photodetectors based on graphene, other two-dimensional materials and hybrid systems
Koppens, F. H. L., Mueller, T., Avouris, P., Ferrari, A. C., Vitiello, M. S., & Polini, M. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.215 · Cited by 3,828
Self-citationTHz imaging and sensing for security applications—explosives, weapons and drugs
Federici, J. F., Schulkin, B., Huang, F., Gary, D., Barat, R., Oliveira, F., & Zimdars, D. (2005) · Semiconductor Science and Technology · doi:10.1088/0268-1242/20/7/018 · Cited by 1,756
Cited by
Photodetectors of 2D Materials from Ultraviolet to Terahertz Waves
Qiu, Q., & Huang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008126 · Cited by 582
Matter manipulation with extreme terahertz light: Progress in the enabling THz technology
Salén, P., Basini, M., Bonetti, S., Hebling, J., Krasilnikov, M., Nikitin, A. Y., Shamuilov, G., Tibai, Z., Zhaunerchyk, V., & Goryashko, V. (2019) · Physics Reports · doi:10.1016/j.physrep.2019.09.002 · Cited by 262
Self-citation
Metadata
- Authors
- Castilla, S., Terrés, B., Autore, M., Viti, L., Li, J., Nikitin, A. Y., Vangelidis, I., Watanabe, K., Taniguchi, T., Lidorikis, E., Vitiello, M. S., Hillenbrand, R., Tielrooij, K.-J., & Koppens, F. H. L.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-03-18
- Volume
- 19
- Issue
- 5
- Pages
- 2765-2773
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2921606515
- Cited by
- 242
- References
- 2
- FWCI
- 10.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast and Sensitive Terahertz Detection Using an Antenna-Integrated Graphene pn Junction. https://app.cochat.ai/papers/10.1021/acs.nanolett.8b04171
- The paper
- Castilla, S., Terrés, B., Autore, M., Viti, L., Li, J., Nikitin, A. Y., Vangelidis, I., Watanabe, K., Taniguchi, T., Lidorikis, E., Vitiello, M. S., Hillenbrand, R., Tielrooij, K.-J., & Koppens, F. H. L. (2019). Fast and Sensitive Terahertz Detection Using an Antenna-Integrated Graphene pn Junction. Nano Letters. https://doi.org/10.1021/acs.nanolett.8b04171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.