Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 242

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Fast and Sensitive Terahertz Detection Using an Antenna-Integrated Graphene pn Junction

Open access
Castilla, Sebastián, Terrés, Bernat, Autore, Marta, Viti, Leonardo, Li, Jian, Nikitin, Alexey Y., Vangelidis, Ioannis, Watanabe, Kenji, Taniguchi, Takashi, Lidorikis, Elefterios, Vitiello, Miriam S., Hillenbrand, Rainer, Tielrooij, Klaas-Jan, Koppens, Frank H.L. · 2019 · Nano Letters

Abstract

Although the detection of light at terahertz (THz) frequencies is important for a large range of applications, current detectors typically have several disadvantages in terms of sensitivity, speed, operating temperature, and spectral range. Here, we use graphene as a photoactive material to overcome all of these limitations in one device. We introduce a novel detector for terahertz radiation that exploits the photothermoelectric (PTE) effect, based on a design that employs a dual-gated, dipolar antenna with a gap of ∼100 nm. This narrow-gap antenna simultaneously creates a pn junction in a graphene channel located above the antenna and strongly concentrates the incoming radiation at this pn junction, where the photoresponse is created. We demonstrate that this novel detector has an excellent sensitivity, with a noise-equivalent power of 80 pW/[Formula: see text] at room temperature, a response time below 30 ns (setup-limited), a high dynamic range (linear power dependence over more than 3 orders of magnitude) and broadband operation (measured range 1.8-4.2 THz, antenna-limited), which fulfills a combination that is currently missing in the state-of-the-art detectors. Importantly, on the basis of the agreement we obtained between experiment, analytical model, and numerical simulations, we have reached a solid understanding of how the PTE effect gives rise to a THz-induced photoresponse, which is very valuable for further detector optimization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.nanolett.8b04171

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 242

Metadata

Authors
Castilla, S., Terrés, B., Autore, M., Viti, L., Li, J., Nikitin, A. Y., Vangelidis, I., Watanabe, K., Taniguchi, T., Lidorikis, E., Vitiello, M. S., Hillenbrand, R., Tielrooij, K.-J., & Koppens, F. H. L.
Venue
Nano Letters
Published
2019-03-18
Volume
19
Issue
5
Pages
2765-2773
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2921606515
Cited by
242
References
2
FWCI
10.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fast and Sensitive Terahertz Detection Using an Antenna-Integrated Graphene pn Junction. https://app.cochat.ai/papers/10.1021/acs.nanolett.8b04171
The paper
Castilla, S., Terrés, B., Autore, M., Viti, L., Li, J., Nikitin, A. Y., Vangelidis, I., Watanabe, K., Taniguchi, T., Lidorikis, E., Vitiello, M. S., Hillenbrand, R., Tielrooij, K.-J., & Koppens, F. H. L. (2019). Fast and Sensitive Terahertz Detection Using an Antenna-Integrated Graphene pn Junction. Nano Letters. https://doi.org/10.1021/acs.nanolett.8b04171

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.