The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Self-Sensing Enzyme-Powered Micromotors Equipped with pH-Responsive DNA Nanoswitches
Abstract
Biocatalytic micro- and nanomotors have emerged as a new class of active matter self-propelled through enzymatic reactions. The incorporation of functional nanotools could enable the rational design of multifunctional micromotors for simultaneous real-time monitoring of their environment and activity. Herein, we report the combination of DNA nanotechnology and urease-powered micromotors as multifunctional tools able to swim, simultaneously sense the pH of their surrounding environment, and monitor their intrinsic activity. With this purpose, a FRET-labeled triplex DNA nanoswitch for pH sensing was immobilized onto the surface of mesoporous silica-based micromotors. During self-propulsion, urea decomposition and the subsequent release of ammonia led to a fast pH increase, which was detected by real-time monitoring of the FRET efficiency through confocal laser scanning microscopy at different time points (i.e., 30 s, 2 and 10 min). Furthermore, the analysis of speed, enzymatic activity, and propulsive force displayed a similar exponential decay, matching the trend observed for the FRET efficiency. These results illustrate the potential of using specific DNA nanoswitches not only for sensing the micromotors' surrounding microenvironment but also as an indicator of the micromotor activity status, which may aid to the understanding of their performance in different media and in different applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seeman, N. C., & Sleiman, H. F. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.68 · Cited by 1,875
Cited by
Principles, mechanisms, and application of carbon quantum dots in sensors: a review
Molaei, M. J. (2020) · Analytical Methods · doi:10.1039/c9ay02696g · Cited by 584
Wang, B., Kostarelos, K., Nelson, B. J., & Zhang, L. (2021) · Advanced Materials · doi:10.1002/adma.202002047 · Cited by 497
Zhang, T., Tian, T., Zhou, R., Li, S., Ma, W., Zhang, Y., Liu, N., Shi, S., Li, Q., Xie, X., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0355-z · Cited by 453
Medical Micro/Nanorobots in Precision Medicine
Soto, F., Wang, J., Ahmed, R., & Demirci, U. (2020) · Advanced Science · doi:10.1002/advs.202002203 · Cited by 442
Smart Materials for Microrobots
Soto, F., Karshalev, E., Zhang, F., Esteban Fernandez de Avila, B., Nourhani, A., & Wang, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00999 · Cited by 433
Metadata
- Authors
- Patino, T., Porchetta, A., Jannasch, A., Lladó, A., Stumpp, T., Schäffer, E., Ricci, F., & Sánchez, S.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-01
- Volume
- 19
- Issue
- 6
- Pages
- 3440-3447
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2914060754
- Cited by
- 177
- References
- 1
- FWCI
- 15.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.