The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Flexible MXene-Decorated Fabric with Interwoven Conductive Networks for Integrated Joule Heating, Electromagnetic Interference Shielding, and Strain Sensing Performances
Abstract
Although flexible and multifunctional textile-based electronics are promising for wearable devices, it is still a challenge to seamlessly integrate excellent conductivity into textiles without sacrificing their intrinsic flexibility and breathability. Herein, the vertically interconnected conductive networks are constructed based on a meshy template of weave cotton fabrics with interwoven warp and weft yarns. The two-dimensional early transition metal carbides/nitrides (MXenes), with unique metallic conductivity and hydrophilic surfaces, are uniformly and intimately attached to the preformed fabric via a spray-drying coating approach. Through adjusting the spray-drying cycles, the degree of conductive interconnectivity for the fabrics is precisely tuned, thereby affording highly conductive and breathable fabrics with integrated Joule heating, electromagnetic interference (EMI) shielding and strain sensing performances. Interestingly, triggered by the interwoven conductive architecture, the MXene-decorated fabrics with a low loading of 6 wt % (0.78 mg cm –2 ) offer an outstanding electrical conductivity of 5 Ω sq –1 . The promising electrical conductivity further endows the fabrics with superior Joule heating performance with a heating temperature up to 150 °C at a supply voltage of 6 V, excellent EMI shielding performance, and highly sensitive strain responses to human motion. Consequently, this work offers a novel strategy for the versatile design of multifunctional textile-based wearable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Cited by
Zhang, Y., Ruan, K., Zhou, K., & Gu, J. (2023) · Advanced Materials · doi:10.1002/adma.202211642 · Cited by 765
Flexible MXene‐Based Composites for Wearable Devices
Ma, C., Ma, M., Si, C., Ji, X., & Wan, P. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009524 · Cited by 544
Sensing with MXenes: Progress and Prospects
Ho, D. H., Choi, Y. Y., Jo, S. B., Myoung, J., & Cho, J. H. (2021) · Advanced Materials · doi:10.1002/adma.202005846 · Cited by 482
Ti3C2Tx MXene-Based Flexible Piezoresistive Physical Sensors
Wang, Y., Yue, Y., Cheng, F., Cheng, Y., Ge, B., Liu, N., & Gao, Y. (2022) · ACS Nano · doi:10.1021/acsnano.1c09925 · Cited by 406
Flexible all-textile dual tactile-tension sensors for monitoring athletic motion during taekwondo
Ma, Y., Ouyang, J., Raza, T., Li, P., Jian, A., Li, Z., Liu, H., Chen, M., Zhang, X., Qu, L., et al. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.105941 · Cited by 145
Self-citation
Metadata
- Authors
- Zhang, X., Wang, X., Lei, Z., Wang, L., Tian, M., Zhu, S., Xiao, H., Tang, X., & Qu, L.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-03-09
- Volume
- 12
- Issue
- 12
- Pages
- 14459-14467
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3011609267
- Cited by
- 358
- References
- 1
- FWCI
- 15.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible MXene-Decorated Fabric with Interwoven Conductive Networks for Integrated Joule Heating, Electromagnetic Interference Shielding, and Strain Sensing Performances. https://app.cochat.ai/papers/10.1021/acsami.0c01182
- The paper
- Zhang, X., Wang, X., Lei, Z., Wang, L., Tian, M., Zhu, S., Xiao, H., Tang, X., & Qu, L. (2020). Flexible MXene-Decorated Fabric with Interwoven Conductive Networks for Integrated Joule Heating, Electromagnetic Interference Shielding, and Strain Sensing Performances. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.0c01182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.