The DOI matches its Crossref record.
KOH-Activated Hollow ZIF-8 Derived Porous Carbon: Nanoarchitectured Control for Upgraded Capacitive Deionization and Supercapacitor
Abstract
Herein, the synergistic effects of hollow nanoarchitecture and high specific surface area of hollow activated carbons (HACs) are reported with the superior supercapacitor (SC) and capacitive deionization (CDI) performance. The center of zeolite imidazolate framework-8 (ZIF-8) is selectively etched to create a hollow cavity as a macropore, and the resulting hollow ZIF-8 (HZIF-8) is carbonized to obtain hollow carbon (HC). The distribution of nanopores is, subsequently, optimized by KOH activation to create more nanopores and significantly increase specific surface area. Indeed, as-prepared hollow activated carbons (HACs) show significant improvement not only in the maximum specific capacitance and desalination capacity but also capacitance retention and mean desalination rates in SC and CDI, respectively. As a result, it is confirmed that well-designed nanoarchitecture and porosity are required to allow efficient diffusion and maximum electrosorption of electrolyte ions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Huang, Q., Sheng, L., Wu, T., Huang, L., Yan, J., Li, M., Chen, Z., & Zhang, H. (2025) · Desalination · doi:10.1016/j.desal.2024.118197 · Cited by 57
Metadata
- Authors
- Kim, M., Xu, X., Xin, R., Earnshaw, J., Ashok, A., Kim, J., Park, T., Nanjundan, A. K., El-Said, W. A., Yi, J. W., Na, J., & Yamauchi, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-08-30
- Volume
- 13
- Issue
- 44
- Pages
- 52034-52043
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3198203382
- Cited by
- 268
- References
- 0
- FWCI
- 11.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.