The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Breathable Strain/Temperature Sensor Based on Fibrous Networks of Ionogels Capable of Monitoring Human Motion, Respiration, and Proximity
Abstract
Wearable strain and temperature sensors are desired for human–machine interfaces, health monitoring, and human motion monitoring. Herein, the fibrous mat with aligned nanofibers of ionic liquid (IL)/thermoplastic polyurethane (TPU) ionogels is fabricated via an electrospinning technique. The resultant fibrous mat is cut into a rectangle specimen and electrodes are loaded along the direction perpendicular to the nanofiber orientation to design a high-performance multimodal sensor based on an ionic conducting mechanism. As a strain sensor, the obtained sensor exhibits a wide strain working range (0–200%), a fast response and recovery (119 ms), a low detection limit (0.1%), and good reproducibility because of the reversible and deformable ionic conductive pathways of the sensor. Moreover, the sensor also exhibits excellent temperature-sensing behaviors, including a monotonic thermal response, high sensitivity (2.75% °C –1 ), high accuracy (0.1 °C), a fast response time (2.46 s), and remarkable repeatability, attributable to the negative temperature coefficient behavior of the IL/TPU fibrous mat. More interestingly, the IL/TPU fibrous sensor possesses good breathability, which is desired for wearable electronics. Because of these excellent sensing capabilities in strain and temperature, the sensor can not only monitor tiny and large human motions but also detect respiration and proximity, exhibiting enormous potential in wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Cited by
Ionogels: recent advances in design, material properties and emerging biomedical applications
Fan, X., Liu, S., Jia, Z., Koh, J. J., Yeo, J. C. C., Wang, C.-G., Surat'man, N. E., Loh, X. J., Le Bideau, J., He, C., et al. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00652a · Cited by 332
Self-citationYao, P., Bao, Q., Yao, Y., Xiao, M., Xu, Z., Yang, J., & Liu, W. (2023) · Advanced Materials · doi:10.1002/adma.202300114 · Cited by 308
Ionogels: Preparation, Properties and Applications
Yan, C., Li, W., Liu, Z., Zheng, S., Hu, Y., Zhou, Y., Guo, J., Ou, X., Li, Q., Yu, J., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202314408 · Cited by 288
Metadata
- Authors
- Chen, J., Wang, F., Zhu, G., Wang, C., Cui, X., Xi, M., Chang, X., & Zhu, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-10-23
- Volume
- 13
- Issue
- 43
- Pages
- 51567-51577
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3209108880
- Cited by
- 160
- References
- 1
- FWCI
- 8.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breathable Strain/Temperature Sensor Based on Fibrous Networks of Ionogels Capable of Monitoring Human Motion, Respiration, and Proximity. https://app.cochat.ai/papers/10.1021/acsami.1c16733
- The paper
- Chen, J., Wang, F., Zhu, G., Wang, C., Cui, X., Xi, M., Chang, X., & Zhu, Y. (2021). Breathable Strain/Temperature Sensor Based on Fibrous Networks of Ionogels Capable of Monitoring Human Motion, Respiration, and Proximity. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.1c16733
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.