The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Ultrastretchable, Self-Healing Conductive Hydrogel-Based Triboelectric Nanogenerators for Human–Computer Interaction
Abstract
The rapid development of wearable electronic devices and virtual reality technology has revived interest in flexible sensing and control devices. Here, we report an ionic hydrogel (PTSM) prepared from polypropylene amine (PAM), tannic acid (TA), sodium alginate (SA), and MXene. Based on the multiple weak H-bonds, this hydrogel exhibits excellent stretchability (strain >4600%), adhesion, and self-healing. The introduction of MXene nanosheets endows the hydrogel sensor with a high gauge factor (GF) of 6.6. Meanwhile, it also enables triboelectric nanogenerators (PTSM-TENGs) fabricated from silicone rubber-encapsulated hydrogels to have excellent energy harvesting efficiency, with an instantaneous output power density of 54.24 mW/m 2 . We build a glove-based human–computer interaction (HMI) system using PTSM-TENGs. The multidimensional signal features of PTSM-TENG are extracted and analyzed by the HMI system, and the functions of gesture visualization and robot hand control are realized. In addition, triboelectric signals can be used for object recognition with the help of machine learning techniques. The glove based on PTSM-TENG achieves the classification and recognition of five objects through contact, with an accuracy rate of 98.7%. Therefore, strain sensors and triboelectric nanogenerators based on hydrogels have broad application prospects in man–machine interface, intelligent recognition systems, auxiliary control systems, and other fields due to their excellent stretchable and high self-healing performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantifying the triboelectric series
Zou, H., Zhang, Y., Guo, L., Wang, P., He, X., Dai, G., Zheng, H., Chen, C., Wang, A. C., Xu, C., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09461-x · Cited by 1,920
Self-citationA droplet-based electricity generator with high instantaneous power density
Xu, W., Zheng, H., Liu, Y., Zhou, X., Zhang, C., Song, Y., Deng, X., Leung, M., Yang, Z., Xu, R. X., et al. (2020) · Nature · doi:10.1038/s41586-020-1985-6 · Cited by 1,624
Self-citationPu, X., Liu, M., Chen, X., Sun, J., Du, C., Zhang, Y., Zhai, J., Hu, W., & Wang, Z. L. (2017) · Science Advances · doi:10.1126/sciadv.1700015 · Cited by 1,218
Self-citationPeng, X., Dong, K., Ye, C., Jiang, Y., Zhai, S., Cheng, R., Liu, D., Gao, X., Wang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aba9624 · Cited by 885
Self-citationMXenes stretch hydrogel sensor performance to new limits
Zhang, Y.-Z., Lee, K. H., Anjum, D. H., Sougrat, R., Jiang, Q., Kim, H., & Alshareef, H. N. (2018) · Science Advances · doi:10.1126/sciadv.aat0098 · Cited by 783
Wang, D., Zhang, D., Yang, Y., Mi, Q., Zhang, J., & Yu, L. (2021) · ACS Nano · doi:10.1021/acsnano.0c09015 · Cited by 687
Self-citationA Flexible Multifunctional Triboelectric Nanogenerator Based on MXene/PVA Hydrogel
Luo, X., Zhu, L., Wang, Y., Li, J., Nie, J., & Wang, Z. L. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104928 · Cited by 574
Self-citationLi, X., He, L., Li, Y., Chao, M., Li, M., Wan, P., & Zhang, L. (2021) · ACS Nano · doi:10.1021/acsnano.1c01751 · Cited by 473
Wang, D., Zhang, D., Li, P., Yang, Z., Mi, Q., & Yu, L. (2021) · Nano-Micro Letters · doi:10.1007/s40820-020-00580-5 · Cited by 471
Self-citationChao, M., He, L., Gong, M., Li, N., Li, X., Peng, L., Shi, F., Zhang, L., & Wan, P. (2021) · ACS Nano · doi:10.1021/acsnano.1c00472 · Cited by 387
Cited by
Recent advances in tannic acid-based gels: Design, properties, and applications
Tang, Z., Chowdhury, I. F., Yang, J., Li, S., Mondal, A. K., & Wu, H. (2025) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2025.103425 · Cited by 70
Yang, B., Cheng, J., Qu, X., Song, Y., Yang, L., Shen, J., Bai, Z., & Ji, L. (2025) · Advanced Science · doi:10.1002/advs.202408689 · Cited by 59
Metadata
- Authors
- Zhang, H., Zhang, D., Wang, Z., Xi, G., Mao, R., Ma, Y., Wang, D., Tang, M., Xu, Z., & Luan, H.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2023-01-19
- Volume
- 15
- Issue
- 4
- Pages
- 5128-5138
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W4317490361
- Cited by
- 330
- References
- 46
- FWCI
- 24.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.